PRODUCT
Auto Lens Edger
SERVICE MANUAL
DOC No.
SCS-I-9ME-091
PREPARE
REVIEW
CONFIRM
DATE
2013.12.25
MODEL
CME-9000
REVISION DATE
REVISON
USE
2013.12.25
2. Remove GUI board and Keypad
1) Disconnect cables
2) Loosen 4 screws of
LCD. Remove LCD with
GUI board
Some cables are tied to cover. Cut cable ties if
necessary
3) Disconnect keypad 2 cables
4) Loosen 5 screws and remove Keypad board
5) Remove keypad