4.0 HARD WIRING INSTALLATION
4.1 Hard Wiring Connection
WARNING: Turn off the appliance completely and let cool before
servicing. Only a qualified service person should service and repair this
electric appliance.
NOTE: A dedicated 15 Amp (or higher) breaker is required.
If it is necessary to hard wire this appliance, a qualified electrician
must remove the cord connection and wire the appliance directly to
the household wiring.
This appliance must be electrically connected and grounded in
accordance with local codes if hard wired. In the absence of local
codes, use the current ANSI/NFPA 70 'National Electrical Code' in the
United States or the current CSA C22.1 'Canadian Electrical Code' in
Canada.
4.1.1 Hard Wiring Installation
Turn off power from circuit breaker before completing any of these
steps.
The wires are labeled by the yellow clips.
1. Remove the cover plate from the bottom of the right side of the
appliance secured by (3) screws, as shown in Figure 4.1.
2. Remove the wire connectors from the power cord as shown in
Figure 4.2. This power cord may be discarded.
3. Take the new cover plate supplied in the components packet
and knock out the 7/8" (22.2mm) hole.
4. Install the electrical grommet through the hole in the cover
plate. Feed wires through the electrical grommet.
5. Using the wire connectors, connect the green ground wires
together, and the neutral white and blue wires together, then the
hot black wires together. See Figure 4.2
6. Re-install cover plate using (3) screws, as shown in Figure 4.1.
Cover plate
Figure 4.1, Cover Plate Removal
Figure 4.2, Remove Wire Connectors to Power Cord
Figure 4.3, Wiring through Electrical Grommet and Cover Plate
Electrical grommet