 ADJUSTMENT

Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

#BHM-52 R.1 May 2020

11.2  Burner Flame Adjustments

WARNING: To avoid property damage or personal injury, allow the 

fireplace ample time to cool before making any adjustments. 

Burner flame appearance and characteristics are affected by 

altitude, fuel quality, venting configuration, and other factors. After 

installation, this appliance may need additional adjustments to 

achieve optimum flame appearance and visual aesthetics.

11.2.1  Burner Venturi

WARNING: VENTURI ADJUSTMENT MUST BE DONE BY A QUALIFIED 

SERVICE TECHNICIAN. 
NOTE: Burner venturi air shutter settings have been factory set. Refer 

to Table 11.3.

When this appliance is first lit, the burner flames will appear blue. 

During the first 15 minutes of operation, flame appearance will 

gradually turn to the desired yellow appearance. If the flames remain 

blue, or become dark orange with evidence of sooting (black tips), 

adjustment of the air shutter opening may be necessary. 
Regardless of venturi orientation, closing the air shutter will achieve a 

desired yellow flame, but may produce soot on the glass. Opening the 

air shutter will cause a short, blue flame that may lift off the burner. 

Table 11.3, Factory Set Venturi Openings

Fuel

Center Burner Venturi

Side Burner Venturi

Natural Gas

1/4” (6.35mm)

1/8” (3.175mm)

Propane

1/2” (12.7mm)

1/4” (6.35mm)

11.2.1.1  Venturi Adjustment

NOTE: If soot is present on the logs, check log placement (section 8.4, 

pg. 48) before adjusting the venturi. 

1.  Remove the safety barrier screen and glass frame assembly.
2.  Remove log set, lava rock, and ember bed media tray. 
3.  Remove refractory panel set or black glass panel set.
4.  Remove the log stop brackets.
5.  Remove the side burners and center burners
6.  Release the burner tube venturis off the burner orifices.
7.  Loosen screw on venturi and adjust as necessary. Re-tighten 

screw.

8.  Reinstall all components previously removed.

IMPORTANT: Slight adjustments to the venturi opening will create 

dramatic results. Adjust at slight increments until desired look is 

achieved. Always burn the fireplace for at least 15 minutes, and 

allow the appliance ample time to cool before making any further 

adjustments. 

Table 11.4, Venturi Adjustment Guidelines

Flame Characteristic

Cause

Solution

Dark, orange flame 

with black tips

Venturi closed too far

Open venturi slightly

Short, blue flames

Venturi open too far

Close setting slightly

Lifting (ghosting) 

flames

Gas pressure too high
Venturi closed too far

Check manometer 

settings
Open venturi setting 

slightly

Figure 11.2, Burner Venturis

Figure 11.3, Flame Appearance and Characteristics

Lazy, yellow flames - no adjustment necessary

Ideal Flame Appearance 

Side burner

venturi (left side)

Side burner

venturi (right side)

Center burner venturi

Venturi(s) settings closed too far. Open venturi(s) slightly.

Dark, orange flames with black tips

Venturi(s) open too far. Close venturi settings(s) slightly.

Short, blue flames

Venturi settings(s) closed too far. Open venturi(s) slightly

OR gas pressure too high - check manometer settings

Lifting (ghosting) flames

Содержание Kozy Heat BELLINGHAM 52

Страница 1: ...home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other...

Страница 2: ......

Страница 3: ...cated not only to functionality and reliability but also customer safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas firep...

Страница 4: ......

Страница 5: ...ertical Natural Draft Vent Termination 39 6 2 Minimum Natural Draft Vent Termination Clearances 40 7 0 VENTING 41 7 1 Approved Vent Systems 41 7 2 Venting Requirements 41 7 3 Natural Draft Vent Restri...

Страница 6: ......

Страница 7: ...period a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above prov...

Страница 8: ...and Propane Installation Code local authorities or codes having jurisdiction in you area regarding derate guidelines 2 1 1 1 US Installations Refer to the American Gas Association guidelines for the g...

Страница 9: ...52Dimensions 269 16 675mm 655 8 1666mm 289 16 725mm 17 432mm 527 16 1332mm 307 8 784mm 41 1047mm 585 8 1489mm 50 1282mm 153 16 385mm 13 349mm 245 16 618mm 6 152mm 33 851mm LEFT SIDE FRONT VIEW TOP VI...

Страница 10: ...appliance and shall be installed for the protection of children and other at risk individuals If the safety barrier screen becomes damaged the barrier shall be replaced with Hussong Mfg Co Inc barrie...

Страница 11: ...y and KZK Installation on page 21 All vented cavity options have the same minimum chamber and ceiling dimension requirements as the standard installation dimensions in this section The fireplace chamb...

Страница 12: ...of the fireplace 2 Align nailing flanges with holes on the outside corners of fireplace with the stand off flanges on the nailing flanges facing away from the fireplace 3 Secure the nailing flanges t...

Страница 13: ...rovides Minimum distance to header Contact point for non combustible material above the fireplace Attachment for the header heat shield 1 Locate the stand off assembly and header heat shield on top of...

Страница 14: ...4 19mm trim 8 203mm Mantel 6 152mm deep from fireplace finishing edge 11 1 2 292mm Minimum rough opening height 50 1 2 1283mm Minimum rough opening width 65 5 8 1667mm Minimum rough opening depth 28 3...

Страница 15: ...width and depth of the appliance This fireplace may be elevated off the floor provided it is properly supported by framing materials and maintains ceiling clearances If installed above floor level a...

Страница 16: ...maintain a 1 25mm clearance to combustibles on all surfaces of the pipe See Figure 3 6 on page 17 3 6 2 Vertical Terminations Follow vent pipe manufacturer s installation instructions for vertical te...

Страница 17: ...ances 73 1854mm 28 730mm Natural gas and propane rigid pipe Natural draft minimum horizontal terminations 28 730mm 88 2235mm 11 279mm 11 279mm minimum clearance between any venting and the top of encl...

Страница 18: ...ea where the appliance is protected from direct precipitation Based on your design options and installation choices standard installation vented cavity or Komfort Zone Kit follow your specific require...

Страница 19: ...mum weatherproof overhang in front and sides M i n i m u m w e a t h e r p r o o f o v e r h a n g i n f r o n t a n d s i d e s Minimum weatherproof overhang in front and sides M i n i m u m w e a t...

Страница 20: ...ee heat transfer kit manuals HTK EXT HTK INT for more information Remove 2 cover plate for a Komfort Zone Kit or vented cavity options for the front or top vent cavity Figure 3 10 Heat Transfer Kit Co...

Страница 21: ...t correspond to the vented cavity option you have chosen See Section 3 8 Heat Distribution Cover Plates on the previous page 2 Remove the convection baffle from the appliance The baffle is secured by...

Страница 22: ...d cavity air discharge opening Figure 3 14 MUST be followed The distance between a sprinkler head and discharge opening cannot be less than 60 1524mm in length at every point from the origin of the di...

Страница 23: ...These are minimum dimensions shown for the air discharge opening and the opening may be increased if desired as long as all requirements are followed It is recommended to limit your opening size for a...

Страница 24: ...he fireplace cavity off it cannot have any vent pipe running through the top with a ceiling firestop This installation method can alleviate any possible concerns with paint discoloration from heat or...

Страница 25: ...ted Cavity Alternative Installation with Overhang 6 152mm 4 101mm 52 1321mm 6 152mm 8 203mm 88 2235mm 3 76mm 60 1524mm Air discharge overhang Air discharge opening front 3 x 52 minimum Enclosure top m...

Страница 26: ...are followed It is recommended to limit your opening for aesthetic purposes and to avoid items falling into the enclosure Figure 3 20 shows the fireplace chamber ending 1 1 2 38mm from the ceiling on...

Страница 27: ...st be installed Air discharge opening Air discharge overhang Air discharge overhang Width of fireplace chamber D MAX MIN MIN MAX MIN 88 2235mm MIN Figure 3 21 Top Vented all 3 sides Cavity Crown Moldi...

Страница 28: ...s The adjacent sidewall minimum clearance is 6 152mm from the side finishing edges of the fireplace See Figure 4 3 on page 31 4 1 3 Facing Requirements Non combustible material is required at the top...

Страница 29: ...203mm 2 64mm 33 850mm 31 786mm 88 2235mm 28 730mm 12 305mm 9 229mm 6 152mm 14 356mm Each square represents 1 25mm of projection Top finishing edge Bottom finishing edge Combustible Floor Non combustib...

Страница 30: ...1 May 2020 Figure 4 2 Standard Installation Non combustible Mantel Clearances 8 203mm 41 1054mm 88 2235mm 28 730mm 12 305mm 9 229mm 6 152mm Each square represents 1 25mm of mantel projection Combustib...

Страница 31: ...BHM 52 R 1 May 2020 Hussong Mfg Co Inc Kozy Heat Fireplaces FACING AND FINISHING 31 Figure 4 3 Adjacent Sidewall Clearances 88 2235mm 6 152mm unlimited...

Страница 32: ...ACING AND FINISHING Hussong Mfg Co Inc Kozy Heat Fireplaces BHM 52 R 1 May 2020 Figure 4 4 Framed Opening Clearances 50 1282mm 2 63mm 655 8 1667mm 307 8 784mm 527 16 1332mm 69 16 167mm 88 2235mm 17 43...

Страница 33: ...G 33 Figure 4 5 Minimum Finishing Dimensions 495 8 1261mm 2 64mm 52 1333mm 33 851mm 81 16 187mm 685 8 1743mm 1 38mm Non combustible material only Combustible material allowed Combustible material allo...

Страница 34: ...ptions based on notched tab position See Figure 4 6 below for a flush or a recessed mount 3 Align the notched tabs located on the back of the safety barrier screen with the slots on the glass valance...

Страница 35: ...terial may be attached to the bottom front cover panel using a silicone sealant that has a 300 F 149 C continuous exposure rating It is acceptable to pre drill holes and to use self tapping screws pri...

Страница 36: ...of projection Top finishing edge Bottom finishing edge Combustible wall finish up to 1 25mm may be installed over cement board and butt up to the finishing edge around the opening 12 305mm 9 229mm 6 1...

Страница 37: ...ustible Wall Finish up to 1 25mm thick 88 2235mm 28 730mm Non combustible zone Non combustible material Air discharge opening Combustible wall finish up to 1 25mm thick may be installed up to the top...

Страница 38: ...of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commo...

Страница 39: ...h Feet Meters Flat to 6 12 1 0 0 30 Over 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0...

Страница 40: ...pply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm K Clearance to mechanical air supply inlet 6 1 83m 3 91cm above if within 10 3m horizontally Massachusetts 10 3...

Страница 41: ...mney Supply Inc VDV HC05 VDV VC05 VDV VCH05 Selkirk 5DT HC 5DT HCR 5DT VT 5DT VC 7 1 2 Approved 4 x 6 5 8 Vent Systems This appliance may be reduced from a 5 x 8 to a 4 x 6 5 8 vent system using a ven...

Страница 42: ...outer most ring knocked out will create the least amount of restriction Follow Figure 7 1 for restrictor plate installation before attaching venting or through the baffle if venting is already attache...

Страница 43: ...tems on page 41 Refer to the vent manufacturer s installation instructions i Minimum Maximum Vertical Terminations 3 914mm minimum vertical length 50 15 24m maximum vertical length termination cap ii...

Страница 44: ...Minimum 36 Vertical Vent Pipe Minimum Maximum Horizontal Termination 36 914mm vertical vent pipe 90 horizontal elbow 6 152mm minimum horizontal 6 1 83m maximum horizontal termination cap iii Minimum 4...

Страница 45: ...Section 7 1 Approved Vent Systems on page 41 Refer to the vent manufacturer s installation instructions For maximum vertical and maximum horizontal combination venting the vent terminations must be w...

Страница 46: ...the bottom frame rail 2 Use the provided tool to pull the 4 latch assemblies to latch with the flange on top of the glass valance 3 Reinstall safety barrier screen BOTTOM FRAME RAIL GLASS VALANCE ON...

Страница 47: ...Side Refractory Panel Installed Figure 8 5 Side Black Glass Panels Installed 8 3 1 Refractory Panels 1 Install back refractory panel Secure with panel clips previously bent See Figure 8 3 2 Install s...

Страница 48: ...ainst the log stop bracket flanges Figure 8 6 2 Use a steel or stiff bristle nylon brush to distribute a thick layer of fine rock wool embers across the whole burner and burner port holes 3 Align the...

Страница 49: ...ith the notches in log BH52 2 and BH52 3 Figure 8 8 Place as shown in Figure 8 10 8 Align log BH52 10 with the notches on logs BH52 9 and BH52 6 Figure 8 9 and place as shown in Figure 8 10 9 Align lo...

Страница 50: ...ace logs BH52 14 and BH52 15 on the ember bed as shown 14 Place the 6 charred pieces on top of the ember bed We show one way to place the pieces and you may place the pieces at your discretion 15 Dist...

Страница 51: ...hen finished 8 5 2 Control Board Removal 1 Disconnect electrical power 2 Locate the manual valve upstream of the appliance connector and close valve 3 Remove the safety barrier screen and glass frame...

Страница 52: ...with screws previously removed 3 Reinstall burner support brackets if removed 4 Reinstall the main log support Align the holes in the main log support with the holes in the firebox back wall and in le...

Страница 53: ...remove the grounding prong from this plug 9 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wit...

Страница 54: ...sconnect all electrical power from the fireplace before performing this task ATTENTION If converting to propane complete the conversion before installing any light kit components Follow instructions p...

Страница 55: ...Remove the safety barrier screen and glass frame assembly if installed 2 Remove the top light kit covers and its roped glass 8 screws total Save screws 3 Install or replace 2 halogen bulbs included wi...

Страница 56: ...pliance 10 Press the wireless remote ON button 11 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INST...

Страница 57: ...in ON OFF toggle switch to ON position for remote control operation of the main burner and fireplace features 7 Reinstall all components previously removed 10 3 Reset the System for Manual Operation 1...

Страница 58: ...sparks for 60 seconds 3 If there is no flame ignition rectification within the 60 second time frame the IFC module will stop generating sparks for approximately 35 seconds 4 After 35 seconds of wait t...

Страница 59: ...ilot system to the standing pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the s...

Страница 60: ...ame levels If the smart thermostat operation is activated then the manual adjustment of the flame height will be disabled 1 Verify the system is in the ON position and the flame level is set at maximu...

Страница 61: ...l will still operate the main burner on and off and function flame fan and light modulation To deactivate this function 1 Verify all 3 AAA batteries are installed in the remote control 2 Remove 1 AAA...

Страница 62: ...3 Press the down arrow key to turn the ember bed light kit OFF 4 A single beep will confirm reception of the command 10 9 11 1 Adjust Ember Bed Light Kit Intensity The ember bed light kit intensity ca...

Страница 63: ...and maximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Reli...

Страница 64: ...cement section 8 4 pg 48 before adjusting the venturi 1 Remove the safety barrier screen and glass frame assembly 2 Remove log set lava rock and ember bed media tray 3 Remove refractory panel set or b...

Страница 65: ...supply and call a qualified service technician 11 2 2 1 Restrictor Plate Installation 1 Remove the safety barrier and the glass frame assembly 2 Locate the 5 127mm exhaust pipe in the firebox ceiling...

Страница 66: ...it No propane in tank Check propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a low l...

Страница 67: ...Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 11 2 1 Burner Venturi on page 64 Incorrect vent cap installation Adjust if necessary Vent cap blo...

Страница 68: ...KPV please reference the manual included with the kit For natural draft vent installation refer to Section 7 0 Venting on page 41 Performed by Qualified Service Person Frequency Annually Action Exami...

Страница 69: ...f the flame safety system Pilot or Flame rectification device Visually check pilot light when in operation Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas va...

Страница 70: ...pane Burner Orifice CENTER 1 90mm 700 2190 Fan Light Kit Wire Harness 700 655 Propane Burner Orifice SIDES 63 700 263 Pilot Assembly Natural Gas 900 064A Conversion Kit Natural Gas NCK BH52 SPB Pilot...

Страница 71: ...12 Log BH52 12 BH52 13 Log BH52 13 BH52 14 Log BH52 14 BH52 15 Log BH52 15 1 2 Lava Rock 600 715 Rock Wool Embers 900 REMB REFRACTORY PANEL SETS Chicago Brick Refractory Set BH52 CB900 Ledgestone Refr...

Страница 72: ...ut not limited to improper chimney venting installation will also render this warranty void 7 This warranty does not cover installation and operational related problems such as environmental condition...

Страница 73: ......

Отзывы: