background image

C

A

B

D

P/N 047

7992

_

A

®

W6RRI

Technical Data Sheet

P/N 047

7992

_

A

February 2007

We reserve the right to change or
revise specifications and product
design in connection with any feature
of our products. Such changes do 
not entitle the buyer to corresponding
changes, improvements, additions 
or replacements for equipment
previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

A.

25W

Energy Efficient Fan Assembly — Discharge 

0477658

Fan Motor, Discharge 

(1)

(MO.4410549)

0463643

Fan Blade  (FB.4780648)

B.

25W

Energy Efficient Fan Assembly — Return

0477658

Fan Motor, Return

(2)

(MO.4410549)

0463643

Fan Blade  (FB.4780648)

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

C. Ballast, Electronic

(4)

0464251

2 lamps

(BA.4481298)

0464252

3 lamps

(BA.4440509)

0464253

4 lamps

(BA.4481299)

D.

Fluorescent Lamp

(5)

Replace with like fixtures

©2006 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Содержание W6RRI

Страница 1: ... Item FAN ASSEMBLIES A 25W Energy Efficient Fan Assembly Discharge 0477658 Fan Motor Discharge 1 MO 4410549 0463643 Fan Blade FB 4780648 B 25W Energy Efficient Fan Assembly Return 0477658 Fan Motor Return 2 MO 4410549 0463643 Fan Blade FB 4780648 Item Part Description Wiring Item LAMPS AND BALLASTS C Ballast Electronic 4 0464251 2 lamps BA 4481298 0464252 3 lamps BA 4440509 0464253 4 lamps BA 4481...

Страница 2: ...e Electrical Field Wiring Connection Point Back of case to center of 4x4x2 Upper Electrical box 2 3 4 71 2 3 4 71 Back of case to center of 2x4x2 Lower Electrical box 47 7 8 1215 47 7 8 1215 RH End of case to center of 4x4x2 Upper Electrical box 2 50 2 50 RH End of case to center of 2x4x2 Lower Electrical box 5 1 8 132 5 1 8 132 Waste Outlet B RH End of case to the center of LH waste outlet canopy...

Страница 3: ...mmended Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control W6RRI CI CO Temp F 12 2 Indoor Unit Only Pressure Defrost Termination Temp F NA Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 7 8 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 8 ft 2 7 12 ft 3 9 This is an average fo...

Страница 4: ... 230V 60Hz Energy Efficient 3 80 5 60 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 2 Row Canopy 1 02 1 54 118 170 Optional Lighting None Shelf Lighting Additional 1 Row Shelf 0 51 0 51 0 77 59 59 85 Additional 2 Row Shelf Maximum 1 02 1 02 1 54 118 118 170 115V Lighting Circuit Total Standard Lighting Total Optional Lighting Optional Shelf...

Страница 5: ...reen BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 2 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 4 6 Return Air Fans 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND ...