VGM, VGD-0505

1 4

Case Specifications

TEMPERATURE

DISCHG.

TYPE

DEFROST

115 V.  ELECTRICAL CIRCUITS

HUMIDITY

MODEL

BTU

AVG

AIR

T-STAT/

FAN SIZE

FREQ.

AIR

AIR

HUNIDITY

 LENGTH

REQ’D

EVAP PROD DISC

VELOC

CUT IN

NUMBER

FAN

&

E E FANS

RECEP-

SWEEP

SWEEP

SYSTEM

APP.

FT.

TMP

TMP

TMP

@FPM

SETTINGS EVAP. COIL

OF MOTORS

QTY

DURATION (STANDARD) LIGHTS

TACLE

FANS

HEATER

FANS

VGD  Deli 

(Blower Coil)

 4'

Deli

750

20

°

34

°

25

°

250

26

°

Forced

Evap 4

1

/

2

" Axial

3

36 min.

54

1.83

15.0

36

1.04

[.16]

Air

Air Sweep 4

1

/

2

" Axial

1

(4)

Humidity 3

1

/

4

” Axial

1

 6'

Deli

750

20

°

34

°

25

°

250

26

°

Forced

Evap 4

1

/

2

" Axial

4

36 min.

1.08

3.66

15.0

72

1.57

[.16]

Air

Air Sweep 4

1

/

2

" Axial

2

(4)

Humidity 3

1

/

4

” Axial

1

 8'

Deli

750

20

°

34

°

25

°

250

26

°

Forced

Evap 4

1

/

2

" Axial

4

36 min.

1.08

3.66

15.0

1.08

2.09

[.16]

Air

Air Sweep 4

1

/

2

" Axial

3

(4)

s

Humidity 3

1

/

4

” Axial

1

10'

Deli

750

20

°

34

°

25

°

250

26

°

Forced

Evap 4

1

/

2

" Axial

6

36 min.

1.62

5.49

15.0

1.08

3.48

[.32]

Air

Air Sweep 4

1

/

2

" Axial

3

(4)

Humidity 3

1

/

4

” Axial

2

12'

Deli

750

20

°

34

°

25

°

250

26

°

Forced

Evap 4

1

/

2

" Axial

6

36 min.

1.62

5.49

15.0

1.08

3.13

[.32]

Air

Air Sweep 4

1

/

2

" Axial

3

(4)

Humidity 3

1

/

4

” Axial

2

NOTE:A. Case temperature is controlled by a factory installed thermostat and suction solenoid (excluding self contained cases),  no other controls are recommended or supported.
B. Data in 

[ ]

  Indicates optional Humidity System.

VGD Deli Wedges

TEMPERATURE

DISCHG.

TYPE

DEFROST

115 V.  ELECTRICAL CIRCUITS

HUMIDITY

MODEL

BTU

AVG

AIR

T-STAT/

FAN SIZE

FREQ.

AIR

AIR

HUNIDITY

 LENGTH

REQ’D

EVAP PROD DISC

VELOC

CUT IN

NUMBER

FAN

&

E E FANS

RECEP-

SWEEP

SWEEP

SYSTEM

APP.

FT.

TMP

TMP

TMP

@FPM

SETTINGS EVAP. COIL

OF MOTORS

QTY

DURATION (STANDARD) LIGHTS

TACLE

FANS

HEATER

FANS

30

°

 / 45

°

Inside

All Loads on Parent Case

Outside

All Loads on Parent Case

90

°

Inside Deli 2,670 20

°

36

°

28

°

200-300

28

°

Forced

Evap 4

1

/

2

" Axial

2

36 min.

.36

1.22

15.0

.18

1.04

Inside Meat

Total

20

°

34

°

26

°

201-300

26

°

Air

Air Sweep 4

1

/

2

" Axial

1

(4)

90

°

Outside Deli 2,670 20

°

36

°

28

°

202-300

28

°

Forced

Evap 4

1

/

2

" Axial

1

36 min.

.18

1.22

15.0

.18

1.04

Outside Meat

Total

20

°

34

°

26

°

200-300

26

°

Air

Air Sweep 4

1

/

2

" Axial

1

(4)

VGM Meat/Fish 

(Gravity Coil)

 4'

Deli

360

15

°

36

°

28

°

28

°

Gravity

Air Sweep 4

1

/

2

" Axial

1

90 min.

-

1.77

15.0

36

1.04

[.16]

(1)

 6'

Deli

360

15

°

36

°

28

°

28

°

Gravity

Air Sweep 4

1

/

2

" Axial

2

90 min.

-

2.93

15.0

72

1.57

[.16]

(1)

 8'

Deli

360

15

°

36

°

28

°

28

°

Gravity

Air Sweep 4

1

/

2

" Axial

3

90 min.

-

3.54

15.0

1.08

2.09

[.16]

(1)

10'

Deli

360

15

°

36

°

28

°

28

°

Gravity

Air Sweep 4

1

/

2

" Axial

3

90 min.

-

n/a

n/a

n/a

n/a

n/a

(1)

12'

Deli

360

15

°

36

°

28

°

28

°

Gravity

Air Sweep 4

1

/

2

" Axial

3

90 min.

-

5.31

15.0

1.08

3.13

[.32]

(1)

NOTE:A. Case temperature is controlled by a factory installed thermostat and suction solenoid (excluding self contained cases),  no other controls are recommended or supported.
B. Data in 

[ ]

  Indicates optional Humidity System.

SELF CONTAINED DATA

BLOWER COIL

GRAVITY COIL

LOW

LOW

PRESSURE

PRESSURE

SETTINGS

H.P.

VOLTS

AMPACITY

SETTINGS

H.P.

VOLTS

AMPACITY

4’

30# Out

1/3

115

10.9

50# in

6’

30# Out

1/2

115

19.9

50# in

8’

30# Out

3/4

208

8.7

50# in

/230

10’

30# Out

1

208

13.0

50# in

/230

12’

30# Out

1

208

13.0

50# in

/230

Содержание VGD

Страница 1: ...VGM VGD Vertical Glass Service Deli Meat Fish Case P N VGM VGD 0505 Chino VGM VGD Vertical Glass Service Deli Meat Fish Case REV 0505 I n s t a l l a t i o n Operation M a n u a l INSTALLATION OPERAT...

Страница 2: ...f Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier immediately and request an inspection Hussmann Chino will acknowledge shortages within ten days from r...

Страница 3: ...perature swings causing product dehydration and excessive energy consumption Defrost cycles should be set according to the Case Specifications in this book Clean humidity system a minimum of every 90...

Страница 4: ...s full extension and lower Installation These steps should release any settled lubricant within the cylinders and prevent any stress on the front glass SETTING AND JOINING The sectional construction o...

Страница 5: ...re by bolting the rear mullions tegether Do not use bolts to pull cases together 9 Apply bead of silicone to top of bulkheads and slip on stainless steel bulkhead cap Also apply silicone to seam betwe...

Страница 6: ...trap supplied with the case 2 When connecting condensate drains the P trap must be used as part of the condensate drain to prevent air leakage or insect entrance Store plumbing system floor drains sh...

Страница 7: ...oduct quality with the installation of the proper controlling devices These should be set according to the Hussmann s specifications and a prop erly maintained humidity system Incorrect settings and f...

Страница 8: ...te on the case for information REFRIGERATION LINES LIQUID SUCTION 3 8 O D 5 8 O D NOTE The standard coil is piped at 5 8 suction however the store tie in may vary depending on the number of coils and...

Страница 9: ...each night with a clean damp cloth or butcher paper never use plastic as it does not allow appearance and significantly shortening product shelf life 10 Cold coils remove heat and moisture from the ca...

Страница 10: ...clean the non glare glass The damage to the glass from improper cautic solutions is irreparable In addition to cleaning the glass with the recommended product there are precautions that should be take...

Страница 11: ...trol is working properly and that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When Contacting the Factory regarding problems Be sure to have the Case MODEL...

Страница 12: ...ction gently tap loose or remove panel wedge the entire length of the panel Maintenance cont FOR PROMPT SERVICE When Contacting the Factory regarding problems Be sure to have the Case MODEL and SERIAL...

Страница 13: ...s Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component This includes but not limited to Fans Heaters Thermostats and Lights ALWAYS DISCONNECT ELECTRI...

Страница 14: ...AIR T STAT FAN SIZE FREQ AIR AIR HUNIDITY LENGTH REQ D EVAP PROD DISC VELOC CUT IN NUMBER FAN E E FANS RECEP SWEEP SWEEP SYSTEM APP FT TMP TMP TMP FPM SETTINGS EVAP COIL OF MOTORS QTY DURATION STANDA...

Страница 15: ...F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F32T8 48 12...

Страница 16: ...FANS 1 COMAIR 125 01 2011 M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28...

Страница 17: ...NS 1 COMAIR 125 01 2011 M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5...

Страница 18: ...03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F3...

Страница 19: ...0311 CIRCUIT 1 W G BK DUPEX OUTLET SINGLE OUTLET W G BK AIR SWEEP FANS 3 COMAIR 00001212 M M M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241...

Страница 20: ...W G BK DUPEX OUTLET SINGLE OUTLET W G BK AIR SWEEP FANS 3 COMAIR 00001212 M M TOP FRONT LIGHTS OPTIONAL LIGHTS TERMINAL BLOCK 125 01 0295 SHELF LIGHT NOSE LIGHT LEDGE LIGHT F21T5 36 125 03 1129 F21T5...

Страница 21: ...complete start up evaluation prior to the loading of food into the refrig erator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant accordi...

Страница 22: ...or blade inoperative 14 Is the defrost time excessive 15 Is the defrost termination thermostat if used set too high 16 Are the refrigerant controls incorrectly adjusted 17 Is the air entering the cond...

Страница 23: ...this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor ass...

Страница 24: ...lar unit They can be found on a small metal plate on the unit Please note them below for future reference M O D E L SERIAL NUMBER Chino Additional copies of this publication may be obtained by contact...

Отзывы: