background image

Rev.0109

23

CASE SCHEMATICS (CONT’D)

DATE:

PRO

JEC

T

 T

ITLE:

DRAW

IN

G

 #

:

DRAWN BY:

PRODUC

T

ION

 ORDER

 #:

DRAW

IN

G

 T

ITLE:

DATE:

Hus

s

m

a

nn

 C

o

rporat

ion,

 I

n

t'l.

13770

 R

a

mo

na 

Avenue

Chi

n

o,

 CA. 

91710

(909)-590-4

910

    

 L

ic

.#

: 6444

06

REV

IS

IO

NS

:

#:    DESCR

IP

T

ION

:

CHECKED

 B

Y

:

BY

:

FI

LE LOCA

TI

ON

:

ADR

IAN E

. CR

IS

C

I

AEC

PA

GE

     

OF
11

06/

28/

01

1      R

EDRAWN

  T

O

 NE

ST

ANDARD 

FR

OM

 10/

25/

99        

06/

2

8/

01  

   AEC

H:\

W

IRESCHE

M

A

T

ICS\NE

W-

W

IR

ING

L

P

H2

L2

L1

H1

12

5-

01-

3182

OM

R

O

N

 RE

LAY

G7

L

-2A-TU

BJ-CB

L1

L2

L3

N

G

L

MA

IN

 P

O

W

E

R

~2

0

8

 / ~

2

40 VAC

 - 

1Ø -

 5

0

/6

0 H

Z

 -

 4

W

BALLA

ST

 125-01-3

267

FULHA

M LH

4-120

-L

RE

LAY

 OM

RON

G7

L-2

A

-TU

B

J-CB

12

5-

0

1

-3

1

8

2

L

CASE

 L

IGH

T

SW

ITCH

CANO

PY

 LI

GH

TS

(2

) F

P

35T

5

/830

IN

F

IN

IT

E

CON

T

R

O

L

125-

01-

166

3

OV

ERHEAD

 HEA

TER HE-

1

3

 58"

(2

) 1760

 W

 / ~

240VAC

125-

01-

1002

A

GR

IDDL

E HE

AT

ERS 

(2

LF + (

2

)RT

225-

01-

6

78

0T + 225-

01-

6781T

(4

) 179

/ ~

2

40VAC

PACK

TR

ON

IC

S

CON

TROLL

ER

225

-01

-3

2

2

9

PIL

O

T

LI

G

H

T

L

TE

M

P

. CON

TRO

L

SENS

OR

225-

01-

3228

6

4

2

1

5

P1

37

NOTE:

 CAS

E M

UST BE

GR

OUNDED

18.4

17.8

~

16.2

15.6

~

L1

L2

L3

208 V 

 240 V

LOADI

NG

RMI

D CASES

W6500004

7' CASE 

HOT TOP WIRING DIAG

RAM

Содержание RMID

Страница 1: ... Chino RMID RMID HT Island Cheese Deli Case Rev 0109 Installation Operation Manual RMID Cheese Deli Island Case p n IGIC RMID RMID HT 0109 INSTALLATION OPERATION GUIDE RMID C ...

Страница 2: ...hipment for any possible shortages of mate rial If a shortage should exist and is found to be the re sponsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier imme diately and request an inspection Hussmann Chino will acknowledge shortages within ten days from receipt of equipment HUSSMANN CHINO PRODUCT CONTROL The serial number and shipping da...

Страница 3: ...le 1 2 48 Various Lengths MECH STUB UP AREA 18 X 18 48 Variable Lengths RMID HT 4 Scale 1 4 48 AIR FLOW OUT IN A I R F L O W O U T I N 6 RMID 4 with Standard CAD Scale 1 2 48 8 Plex Perimeter 26 7 1 2 Lights 35 1 2 36 19 3 4 6 6 Lights 20 48 Variable Lengths RMID HT 4 OCTAGON Scale 1 4 MECH STUB UP AREA 18 X 18 12 1 8 3 2 3 4 10 15 8 26 7 1 2 35 1 2 36 1 4 19 3 4 Ref Display Lights Lights Food War...

Страница 4: ... joined prior to shipment to insure the closest possible fit when cases are joined in the field When joining use a carpenters level and shim legs accordingly Case must be raised correctly under legs where support is best to prevent damage to case 1 Check floor where cases are to be set to determine the highest point of the floor cases will be set off this point 2 Set first case and adjust legs ove...

Страница 5: ... the store Install P traps oil traps at the base of all suction line ver tical risers Pressure drop can rob the system of capacity To keep the pressure drop to a minimum keep refrigerant line run as short as possible using the minimum number of elbows Where elbows are required use long radius elbows only CONTROL SETTINGS See the Case Specs section of this guidebook for the appropriate settings for...

Страница 6: ...CTRICAL SERVICE RECEPTACLES When Applicable The receptacles located on the exterior of the merchan diser are intended for scales and lighted displays They are not intended nor suitable for large motors or other external appliances BEFORE SERVICING Always Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component This includes but not limited to Fans Hea...

Страница 7: ...ate in the space between the back interior wall bottom and the evaporator coil This should be cleaned out using a low pressure water hose and a bottle brush to loosen up and flush the debris under the coil into the drain trough See precaution below D Apply the sanitizing solution according to the manufacturer s directions E Rinse thoroughly F Dry completely before resuming operation CLEANING MIRRO...

Страница 8: ...u are replacing Remove chan nel CORNER BUMPER CORNER BUMPER UPPER FLARE BUMPER CHANNEL POP RIVET HOLES A B C liquid antistatic coatings should be applied in a very thin even coat If beads appear as it is applied the coat is too thick and the excess should be removed with another cloth Allow the coating to dry then bring to a high gloss with a soft cloth Maintenance BEFORE SERVICING Always Disconne...

Страница 9: ...poundA Base Resin in Dixie cup everything is premeasured at 20 partsA to 1 part B 2 Stir mixture well with stick for 1 to 2 minutes Stir evenly and slowly to prevent excess air and bubbles from entering the mixture 3 Pour mixture from dixie cup into application bottle provided 4 Place rag over bottle and cup it in your hand Rag will allow bottle to spin freely and protect your hand from burning 5 ...

Страница 10: ...w freely Use only what is needed to bind the edges Over flow can scar the plexiglass and needs to be cleaned up immediately with a CLEAN LINT FREE TOWEL OR RAG You may need to apply a small amount of pres sure to the cement to help it flow out of the tube 5 Allow glue to set for at least 15 minutes REPLACE FLARE AND BUMPER 1 Replace flare taking care not to bend it See first il lustration A C in i...

Страница 11: ...4 1 2 4 40 3 0 72 0 61 30 50 3 4 208 230 8 7 Air Axial 7 850 5 950 20 36 28 125 150 30 Forced 4 1 2 6 40 3 1 08 1 22 30 50 1 208 230 13 0 Air Axial 8 850 6 800 20 36 28 125 150 30 Forced 4 1 2 6 40 3 1 08 1 22 30 50 1 208 230 13 0 Air Axial 10 850 8 500 20 36 28 125 150 30 Forced 4 1 2 8 40 3 1 44 1 22 30 50 1 208 230 13 0 Air Axial 12 850 10 200 20 36 28 125 150 30 Forced 4 1 2 8 40 3 1 44 1 83 3...

Страница 12: ...ILE LOCATION ADRIAN E CRISCI AEC PAGE OF 1 1 07 02 01 H WIRESCHEMATICS NEW WIRING 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BUNDLE COLOR ORANGE LIGHT SWITCH L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN L1 N 115 VAC 50 60 Hz EVAPORATOR FAN MOTORS 2 4 AXIAL FANS CENTER AIR DISCHARGE LIGHTING 2 FP14T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L M M RMID CASES W4000001 4 CA...

Страница 13: ...LE LOCATION ADRIAN E CRISCI AEC PAGE OF 1 1 07 02 01 H WIRESCHEMATICS NEW WIRING 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BUNDLE COLOR ORANGE LIGHT SWITCH L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN L1 N 115 VAC 50 60 Hz EVAPORATOR FAN MOTORS 4 4 AXIAL FANS CENTER AIR DISCHARGE LIGHTING 2 FP28T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L M M M M RMID CASES W4000002 6...

Страница 14: ... E CRISCI AEC PAGE OF 1 1 07 02 01 H WIRESCHEMATICS NEW WIRING 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BUNDLE COLOR ORANGE LIGHT SWITCH L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN L1 N 115 VAC 50 60 Hz EVAPORATOR FAN MOTORS 6 4 AXIAL FANS CENTER AIR DISCHARGE LIGHTING 4 FP21T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L M M M M M ...

Страница 15: ...5 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP35T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 13 58 2 1760 W 240VAC 125 01 1002A GRIDDLE HEATERS 2 LF 2 RT 225 01 6780T 225 01 6781T 4 179W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PIL...

Страница 16: ...ELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 3 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 4 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 4 1000 W 240VAC 125 01 3233A GRIDDLE HEATERS 2 LF 2 RT 225 01 6773T 225 01 6774T 4 233W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP...

Страница 17: ...ON G7L 2A TUBJ CB 3 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 4 FP28T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 13 58 4 1760 W 240VAC 125 01 1002A GRIDDLE HEATERS 2 LT 2 RT 2 CT 225 01 6773T 225 01 6774T 225 01 6779T 4 233W 240VAC 2 165W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 BALLAST 125 01 3267 FULHAM LH4 120 L L1 L2...

Страница 18: ...OCATION ADRIAN E CRISCI AEC PAGE OF 1 1 07 02 01 H WIRESCHEMATICS NEW WIRING 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BUNDLE COLOR ORANGE LIGHT SWITCH L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN L1 N 115 VAC 50 60 Hz EVAPORATOR FAN MOTORS 4 4 AXIAL FANS CENTER AIR DISCHARGE LIGHTING 2 FP21T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L M M M M RMID CASES W4000007 5 CAS...

Страница 19: ...TION ADRIAN E CRISCI AEC PAGE OF 1 1 07 02 01 H WIRESCHEMATICS NEW WIRING 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BUNDLE COLOR ORANGE LIGHT SWITCH L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN L1 N 115 VAC 50 60 Hz EVAPORATOR FAN MOTORS 4 4 AXIAL FANS CENTER AIR DISCHARGE LIGHTING 2 FP28T5 830 BALLAST 125 01 3266 FULHAM LH3 120 L M M M M RMID CASES W4000008 6 CASE C...

Страница 20: ...P H2 L2 L1 H1 PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 125 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 2 1000 W 240VAC 125...

Страница 21: ...2 L2 L1 H1 PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 125 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 2 1000 W 240VAC 125 01...

Страница 22: ... 125 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP28T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 01 46 2 1400 W 240VAC 125 01 3232A GRIDDLE HEATERS 2 LF 2 RT 225 01 6780T 225 01 6781T 4 179W 240VAC PACKTRONICS CONTROLLER 225 01 3229 ...

Страница 23: ...5 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP35T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 13 58 2 1760 W 240VAC 125 01 1002A GRIDDLE HEATERS 2 LF 2 RT 225 01 6780T 225 01 6781T 4 179W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PIL...

Страница 24: ...ELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 3 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 4 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 4 1000 W 240VAC 125 01 3233A GRIDDLE HEATERS 2 LF 2 RT 225 01 6773T 225 01 6774T 4 233W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP...

Страница 25: ...ON G7L 2A TUBJ CB 3 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 4 FP28T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 13 58 4 1760 W 240VAC 125 01 1002A GRIDDLE HEATERS 2 LT 2 RT 2 CT 225 01 6773T 225 01 6774T 225 01 6779T 4 233W 240VAC 2 165W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 BALLAST 125 01 3267 FULHAM LH4 120 L L1 L2...

Страница 26: ...OMRON G7L 2A TUBJ CB 3 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 4 FP35T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 05 67 4 2100 W 240VAC 125 01 3236A GRIDDLE HEATERS 2 LT 2 RT 4 CT 225 01 6773T 225 01 6774T 225 01 6779T 4 233W 240VAC 4 165W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 BALLAST 125 01 3267 FULHAM LH4 120 L L1...

Страница 27: ... PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 125 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 2 1000 W 240VAC 125 01 3233A GRI...

Страница 28: ... H1 PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L TEMP CONTROL SENSOR 225 01 3228 6 4 2 1 5 P1 3 7 125 01 3182 OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP21T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 02 34 2 1000 W 240VAC 125 01 3233A ...

Страница 29: ...OMRON RELAY G7L 2A TUBJ CB L1 L2 L3 N G L MAIN POWER 208 240 VAC 1Ø 50 60 HZ 4W BALLAST 125 01 3267 FULHAM LH4 120 L RELAY OMRON G7L 2A TUBJ CB 125 01 3182 L CASE LIGHT SWITCH CANOPY LIGHTS 2 FP28T5 830 INFINITE CONTROL 125 01 1663 OVERHEAD HEATER HE 01 46 2 1400 W 240VAC 125 01 3232A GRIDDLE HEATERS 2 LF 2 RT 225 01 6780T 225 01 6781T 4 179W 240VAC PACKTRONICS CONTROLLER 225 01 3229 PILOT LIGHT L...

Страница 30: ...FROST TIMER PARAGON 8045 00 115 V 60 Hz 125 01 0710 RED YELLOW BLACK BLUE POWER 115 VAC 60 Hz 3 WIRES S C R C 2 1 3 R S T X 4 N 3 1 2 N L COMPRESSOR MOTOR CONDENSER FAN START CAPACITOR EXTERNAL PROTECTOR T STAT PRESSURE SAFETY POWER SWITCH DEFROST TIMER PARAGON 8045 00 115 V 60 Hz 125 01 0710 5 2 1 POTENCIAL RELAY RED YELLOW BLUE BLACK POWER 115 VAC 60 Hz 3 WIRES M 1 4 HP CONDENSING UNIT 1 3 HP CO...

Страница 31: ...5 01 0002 2 3 HP CONDENSING UNITS 3 4 1 HP CONDENSING UNITS S C R M C 2 1 3 R S T X 4 N 3 1 2 L1 L2 COMPRESSOR MOTOR CONDENSER FAN 208 VAC START CAPACITOR EXTERNAL PROTECTOR T STAT PRESSURE SAFETY POWER SWITCH DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 5 2 1 POTENCIAL RELAY RED YELLOW BLUE BLACK RUN CAPACITOR POWER 208 230 VAC 60 Hz 3 WIRE 1 HP CONDENSING UNIT S C R M C 2 1 3 R S T X 4 ...

Страница 32: ...allation of the system which dispenses condensate waste through an air gap into the building indirect waste system 1 4 The installer should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to Hussmann s recommendations b Observation of ou...

Страница 33: ...mped display causing turbulent air flow and mixing with room air 6 Are spotlights or other high intensity lighting directed onto the product 7 Are there unusual draft conditions from heating air conditioning ducts open doors etc 8 Is there exposure to direct sunlight 8 Are display signs blocking or diverting airflow 9 Are the coils of the refrigerator iced up 11 Is the store ambient over 75 F 55 R...

Страница 34: ...of meat is not to be worked on immediately the procedure should call for returning it to refrigeration h Keep tools clean and sanitized Since mechanical equipment is used for fresh meat processing all such equipment should be cleaned at least daily and each time a different kind of meat product comes in contact with the tool or equipment i Make sure that all refrigeration equipment is installed an...

Страница 35: ...e at an unsafe serving temperature 12 Clean spills as they happen simply by wiping with a cloth Be sure to use a dry cloth on very hot surfaces to prevent steam burns 13 Turn the equipment off and allow to cool before cleaning 14 To remove baked on splatter from Stainless Steel the following may be used Grade F Italian Pumice Scour or rub with a damp cloth Liquid Nusteel Scour with a small amount ...

Страница 36: ...IGIC RMID 0109 36 ...

Страница 37: ...under this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor assembly is available but must be purchased prior to shipment to be in effect Hussmann reserves the right to inspect the job site installation and reason for failure The motor compressor warranties ...

Страница 38: ...rticular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by contacting Hussmann Chino 13770 RamonaAvenue Chino California 91710 909 628 8942 FAX 909 590 4910 800 395 9229 Service Record Last service date By ...

Отзывы: