P/N 0492425_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

L

EVI

T

O N

13451-

20 13451-

20

T8

LA

M

P

T8

LA

M

P

L

EVI

T

O N

13451-

20

T8

LA

M

P

13451-

20

L

EVI

T

O N

T8

LA

M

P

L

EVI

T

O N

40

 1/8

 

(1019)

53

 7/8

 

(1674)

9

 7/8

 

(251)

14

 1/8

 

(359)

11

 1/2

 

(292)

11

 1/2

 

(292)

6

 

(152)

49

 

(1245)

72

 

(1829)

10

 7/8

 

(276)

3

 

1/4

 

(83)

5

 

7/8

 

(149)

3

 

 (76)

27

 

 (686)

15 

 

(381)

13 

 

(330)

10 

 

(254)

Dimensions shown as in. and (mm).

REFRIGERATION DATA

Note: 

This data is based on store tempera-

ture and humidity that does not exceed
75

°

F and 55% R.H. 

RI4

Discharge Air (°F)

27

Evaporator (°F)

20

Unit Sizing (°F)

18

Btu/hr/ft

L

IT

& U

NLIT

S

HELVES

RI4

Parallel

2292

Conventional

2500

DEFROST DATA

RI4

Frequency (hr)

4

Defrost Water (lb/ft/day)

12

(± 15% 

based on case configuration and 

product loading).

O

FF

T

IME

RI4

Time Terminated (minutes)

20

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

RI4

14°F / 4°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to 
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

5

/

8

Estimated Charge (lb)**

8 ft 

1.8

10 ft 

2.2

12 ft 

2.6

14 ft

3.2

16 ft

3.8

**This is an average for all refrigerant types.
Actual refrigerant charge may vary 
by approximately half a pound.

RI4

Multi-deck Island

NSF Certification

These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF

®

) Standard #7 requirements. 

Multi-deck Island, 4 Display Levels

RI4

Load Limit

Load Limit

LEVITON

13451-20

T8

LAMP

13451-20

T8

LAMP

LEVITON

T8

LAMP

13451-20

LEVITON

13451-20

LEVITON

T8

LAMP

RI4

Optional High Plex 
with 6 in. (152 mm) 
Product Depth

Load Limit Profile

Air flow between the shelves, from the CAD to the return, must be maintained at all times
for optimum operating efficiency and to prolong product shelf life. At no time should 
merchandisers be stocked beyond the load limits indicated.

Cases may not function properly if they are loaded above load limits.

Содержание RI4

Страница 1: ...Part Description Wiring Item LAMPS AND BALLASTS C Ballast Electronic 3 0459491 Canopy BA 4481566 D Ballast Electronic 4 0447739 T5 Shelf Lamp BA 4480900 0466234 T8 Shelf Lamp 2 BA 4480823 0466235 T8 Shelf Lamp 3 BA 4480901 E Fluorescent Lamp 5 Replace with like fixtures 2006 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reser...

Страница 2: ...8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 ...

Страница 3: ...r Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 8 10 ft 2 2 12 ft 2 6 14 ft 3 2 16 ft 3 8 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound R...

Страница 4: ...d 4 10 5 40 6 70 8 00 9 30 120V 50Hz Standard 4 70 6 20 7 70 9 20 10 70 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 00 2 60 3 20 3 80 4 40 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 15 Standard Lighting 2 Rows of Canopy 1 75 2 10 2 57 3 03 4 20 320 38...

Страница 5: ...ND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost BROWN BAND BROWN BAND 120V POWER Fans 1 120V NEUTRAL BROWN BAND BROWN BAND 8 ft 10 ft 12 ft 14 ft 16 ft 6 8 10 12 14 Fans HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Страница 6: ... B L B G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 3 5 5 5 Optional Ledge Light Circuit W B Typical Shelf Ballast Wiring Maximum lamps per ballast is three 3 Different s...

Отзывы: