background image

4 of 6

RI2N

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

RI2N

Multi-deck Island

Electrical Data

8 ft

10 ft

12 ft

14 ft

16 ft

Number of Fans – 12W

4

6

8

10

12

Amperes

Watts

8 ft

10 ft

12 ft

14 ft

16 ft

8 ft

10 ft 12 ft 14 ft 16 ft

Evaporator Fan

120V

60Hz

Standard

2.60

3.90

5.20

6.50

7.80

200

300

400

500

600

120V

50Hz

Standard

3.00

4.50

6.00

7.50

9.00

228

342

456

570

684

230V

60Hz

Export

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

230V

50Hz

Export

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

120V

60Hz

Energy Efficient

1.20

1.80

2.40

3.00

3.60

72

108

144

180

216

230V

60Hz

Energy Efficient

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

Anti-sweat Heaters

120V

50/60Hz Standard

0.70

0.70

0.90

1.10

1.30

84

84

108

132

156

230V

50/60Hz Export

0.37

0.37

0.47

0.57

0.68

84

84

108

132

156

Minimum Circuit Ampacity (MCA)

120V

60Hz

Standard

3.97

5.27

6.90

8.53

10.17

120V

50Hz

Standard

3.81

5.31

6.98

8.66

10.33

230V

60Hz

Export

NA

NA

NA

NA

NA

230V

50Hz

Export

NA

NA

NA

NA

NA

120V

60Hz

Energy Efficient

2.01

2.61

3.38

4.16

4.93

230V

60Hz

Energy Efficient

NA

NA

NA

NA

NA

Maximum Over Current Protection 120V

20

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

15

Standard Lighting

1 Row Canopy

0.53

0.53

0.83

1.07

1.37

64

64

100

128

164

Optional Lighting

1 Row of Ledge

1.67

2.00

2.33

2.67

3.00

200

240

280

320

360

Optional Shelf Lighting

1 Row of Shelves

0.82

0.82

1.12

1.35

1.65

98

98

134

162

198

2 Rows of Shelves

1.63

1.63

2.23

2.70

3.30

196

196

268

324

396

115V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52

does not

Содержание RI2N

Страница 1: ...geration Thermostat 2 0448347 CT 4481631 Item Part Description Wiring Item HEATERS C Anti Sweat Heater 3 0487118 HE 4850668 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 E Fluorescent Lamp 5 Replace with like fixtures 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reser...

Страница 2: ... 8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93...

Страница 3: ...st Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 7 10 ft 2 1 12 ft 2 5 14 ft 3 1 16 ft 3 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound NSF Certification These mer...

Страница 4: ...0 60Hz Export 0 37 0 37 0 47 0 57 0 68 84 84 108 132 156 Minimum Circuit Ampacity MCA 120V 60Hz Standard 3 97 5 27 6 90 8 53 10 17 120V 50Hz Standard 3 81 5 31 6 98 8 66 10 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 01 2 61 3 38 4 16 4 93 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over C...

Страница 5: ...ers BROWN BAND Fans BROWN BAND 120V POWER 1 BROWN BAND BROWN BAND 120V NEUTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Страница 6: ...B G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf confi...

Отзывы: