background image

3 of 4

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0384136B

Impact  

PWE

Produce

Produce Wide Island End, 1 Display Level

44

(1118)

30 

3

/

8

(772)

15

(381)

24 

1

/

2

(622)

(76)

12 

3

/

8

(314)

20 

1

/

4

(514)

7

/

(149)

3

/

8

(238)

17

(432)

37 

1

/

4

(946)

16 

5

/

8

(422)

25 

1

/

2

(648)

17 

3

/

8

(441)

PWE

27 

7

/

8

(708)

FAN 

COIL 

Optional

Rack

Positions

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements.

Dimensions are shown as inches & (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

PWE

PWEE

Discharge Air (°F)

32

32

Evaporator(°F)

21

24

Unit Sizing (°F)

19

22

Btu/hr/case*

PWE

PWEE

Parallel

2860

2475

Conventional

3155

2730

*

For all refrigeration equipment other than

Hussmann, use conventional Btu values.

DEFROST DATA

PWE

PWEE

Frequency (hr)

6

6

Defrost Water (lb/ft/day)

8

8

(± 15% 

based on case configuration and

product loading).

O

FFTIME

PWE

PWEE

Temp Term (°F)

N/A

N/A

Failsafe (minutes)

45

45

CONVENTIONAL  CONTROLS

Low Pressure Backup Control

PWE

PWE

CI/CO**

14°/4° F 17°/ 7° F

Indoor Unit Only, Pressure Defrost

Termination**

48° F

48° F

**Use a Temperature Pressure Chart to

determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

PWE

1.0

PWEE

1.1

***

This is an average for all refrigerant types.

Actual refrigerant charge may vary by 

approximately half a pound.

Length Added to Lineup by

Each End/Partition (in.)

1

/

2

Содержание PWE

Страница 1: ...cription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Страница 2: ...includes bumper 74 5 8 1895 74 5 8 1895 Left side of case to outside edge of righthand base rail 57 5 8 1464 57 5 8 1464 Width of case 37 1 4 946 37 1 4 946 Front of base rail to rear of case 20 1 4 514 20 1 4 514 Front of case to outside edge of base rail 17 432 17 432 Front of splashguard to outside edge of base rail 5 7 8 149 5 7 8 149 Width of base rail 2 1 8 54 2 1 8 54 Access area between fr...

Страница 3: ... F 21 24 Unit Sizing F 19 22 Btu hr case PWE PWEE Parallel 2860 2475 Conventional 3155 2730 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA PWE PWEE Frequency hr 6 6 Defrost Water lb ft day 8 8 15 based on case configuration and product loading OFFTIME PWE PWEE Temp Term F N A N A Failsafe minutes 45 45 CONVENTIONAL CONTROLS Low Pressure Backup Control ...

Страница 4: ... 47 70 70 Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 97 0 97 With Energy Efficient Fans 120V 60Hz 0 58 0 58 With Export Fans 230V 50 Hz 0 67 0 67 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None 120V POWER 120V NEUTRAL Fan Wiring Offtime Defrost WARNING All components must h...

Отзывы: