Proto-Aire EZ I/O Manual
P/N
3090249_E
8
57 60
AIR INTAKE
AIR DISCHARGE
CONDENSER
SUCTION FILTERS
OPTIONAL VERTICAL
ORIENTATION IS
AVAILABLE
LIQUID DRIER
OPTIONAL VERTICAL
ORIENTATION IS
AVAILABLE
SCROLL COMPRESSORS
OIL SEPARATOR
CONTROL PANEL
OIL FILTER
OIL MANIFOLD
61.15
49.85
57.00
HINGED
TOP
COVERS
33"
OUTER SPLIT
HINGED
EXTERIOR
DOORS
Small Unit
Large Unit
Approximate Operating Weight (lbs.)
2180
2737
Shipping Weight
2080
2637
Refrigerant
R448A/R449A/407A/407F/404A
Unit Charge (Summer) lbs
2 Row – 8; 5 Row – 15; 6 Row – 22
LAHB13412/10 – 15.4; LAHB13310 –
12.1
Unit Charge (Winter)
2 Row – 24; 5 Row – 56; 6 Row – 82
LAHB13412/10 – 61.6; LAHB13310 –
R448A/R449A/407A/407F/404A
45.4
Receiver Capacity at 80%
98
98
MINIMUM CLEARANCE REQUIREMENTS:
Provide clearances as shown on Pages 8 and 9 to ensure adequate airflow, reduce the potential
for air recirculation, facilitate service accessibility, and to maintain compliance with electrical
code requirements. It is the responsibility of the installer to ensure that the final equipment
installation meets all applicable code requirements. Suggested rigging setup is illustrated. Be sure
that lifting cables/straps do not damage piping stubs, coil surface, or rain guard. Full perimeter
support under unit rail foundation required.
Proto-Aire EZ — Physical Data