background image

6 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P4X-EP 

Technical Data Sheet

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

2, 4 & 6 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 
 

4 ft 
6 ft 
8 ft 

12 ft

12 ft

4

4

3

3

3

4

4

4

4

4

4

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

4

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

4

3

4

4

Connector

W

B

BL

BL

R

BL

R

R

R

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Содержание P4X-EP

Страница 1: ...B 4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY C Ballast Electronic 3 0480130 2 lamps...

Страница 2: ...nal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 24 612 2...

Страница 3: ...re Pressure Chart to determine PSIG conversions Estimated Charge lbs P4X EP 4 ft 1 9 6 ft 2 6 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound 3 of 9 P N 0463874_C 81 3 4 2077 31 5 8 804 30 1 4 768 42 1064 33 1 2 851 26 1 4 665 Refrigeration Outlet 30 1 4 768 53 7 8 1369 34 5 8 878 47 3 4 1212 FAN C O I L P4X EP 24 5 8...

Страница 4: ...ficient 0 80 0 96 1 40 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 2 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 3 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170...

Страница 5: ... Display Area 3 Sq Ft Ft 4 40 ft2 ft 1 34 m2 m Shelf Area 4 Sq Ft Ft 6 88 ft2 ft 2 10 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf su...

Страница 6: ...onal Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED...

Страница 7: ...NG All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelves 4 ft case Connector 4 3 4 4 4 B W Connector 6 ft or 8 ft case 12 ft case BL BL R R BL R BL W W R B R BL BL R 3 B BL BL BL BL R R R R 4 3 4 4 4 B W BL BL R R BL R BL W W R B R BL BL R 3 B BL BL BL B...

Страница 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...

Страница 9: ...BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...