P/N 0515388_L
2-5
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Medium Temperature
Excel
with
EcoVision II Doors
MERCHANDISER ELECTRICAL DATA
Technical data sheets are included with this
manual. The data sheets provide merchandiser
electrical data, electrical schematics, parts lists
and performance data. Refer to the technical
data sheets and merchandiser serial plate for
electrical information.
ELECTRICAL CONNECTIONS
All wiring must be in compliance with NEC
and local codes. All electrical connections are
to be made in the electrical raceway or
Handy
Box
.
FIELD WIRING
Field wiring must be sized for component
amperes stamped on the serial plate. Actual
ampere draw may be less than specified. Field
wiring from the refrigeration control panel to
the merchandisers is required for defrost
termination thermostats and for optional
refrigeration thermostats. When multiple
merchandisers are on the same defrost circuit,
the defrost termination thermostats are wired
in series.
a l w a y s
c h e c k
t h e
s e r i a l
p l a t e
f o r
c o m p o n e n t
a m p e r e s
.
IDENTIFICATION OF WIRING
Leads for all electrical circuits are identified by
colored plastic bands. These bands correspond
to the
color code sticker
(shown below) located
inside the merchandiser’s raceway cover.
WIRING COLOR CODE
Leads for all electrical circuits are identified by a colored plastic band: neutral
wire for each circuit has either White insulation or a White plastic sleeve in
addition to the color band.
P
ink
............ R
efRig
. T
heRmosTaT
L
ow
T
emP
.
o
Range
oR
L
ighT
B
Lue
. R
efRig
. T
heRmosTaT
n
oRm
T
emP
.
T
an
.........L
ighTs
D
aRk
B
Lue
.. D
efRosT
T
eRm
. T
heRmosTaT
m
aRoon
..R
ecePTacLes
P
uRPLe
....... c
onDensaTe
h
eaTeRs
Y
eLLow
...D
efRosT
h
eaTeRs
120V
B
Rown
........ f
an
m
oToRs
R
eD
........D
efRosT
h
eaTeRs
208V
g
Reen
* ....... g
RounD
*e
iTheR
coLoReD
s
LeeVe
o
R
c
oLoReD
i
nsuLaTion
ELECTRICIAN NOTE: Use copper conductor wire only.
MERCHANDISER MUST BE GROUNDED
Optional T8 rail lights and
optional Quick Connect spray hose
or field-installed misting system
shall not be used together.
t
hese
aRe
maRkeR
coloRs
wIRes
may
vaRy
.