background image

P/N 3104942_B

 

2-3

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483  U.S.A.

SHM-A Merchandisers

Before Beginning Any Service or Repair:

Use a hand-held propane leak detector (“sniffer”) 
to ensure no propane is present in the immediate 
area, the inside of the display case and the inside 
of the refrigeration system. R-290 is an odorless 
refrigerant. Keep the area clear of all customers 
and non-essential or unauthorized personnel.

Verify that all repair parts are identical models 
to the ones they are replacing. Do not substitute 
parts such as motors, switches, relays, heaters, 
compressors, power supplies or solenoids. 
Failure to do so can result in an explosion, 
death, injury and property damage. Parts 
used on hydrocarbon cases must meet specific 
UL certification for non-incendive or non-
sparking components. Use only Hussmann 
approved parts approved through the Hussmann 
Performance Parts Website

https://parts.

hussmann.com/

Brazing must not begin before all propane has 
been cleared from the immediate area — the 
inside of the displays case and the inside of the 
refrigeration system.

Only Hussmann or factory 
trained technicians should 
service or repair this R-290 
(propane) equipment.

Failure to follow 
instructions can result in 
an explosion, death, injury 
and property damage.

If a leak is detected, follow store safety 
procedures. It is the store’s responsibility to have 
a written safety procedure in place. The safety 
procedure must comply with all applicable codes 
such as local fire department’s codes.

At minimum, the following actions are required:
•  Immediately evacuate all persons from the 
store, and contact the local fire department to 
advise them that a propane leak has occurred.
•  Call Hussmann and/or a qualified service 
agent and inform them that a propane sensor has 
detected the presence of propane.
•  Do not let any persons back into the store 
until the qualified service technician has arrived 
and that technician advises that it is safe to 
return to the store.

•  The propane gas used in the unit has no odor. 
The lack of smell does not indicate a lack of 
escaped gas.
•  A hand-held propane leak detector 
(“sniffer”) should be used before any repair and/
or maintenance is attempted. All repair parts 
must be identical models to the ones they are 
replacing.
•  No open flames, cigarettes or other possible 
sources of ignition should be used inside the 
building where the units are located until the 
qualified service technician and/or local fire 
department determines that all propane has been 
cleared from the area and from the refrigeration 
systems.

Содержание microSC SHM-A Series

Страница 1: ...be circulated by the fans If propane gas is present or even suspected do not allow untrained personnel to attempt to nd the cause The propane gas used in the unit has no odor The lack of smell does n...

Страница 2: ...is present or even suspected do not allow untrained personnel to attempt to find the cause The propane gas used in the unit has no odor The lack of smell does not indicate a lack of escaped gas If a l...

Страница 3: ...Recover Refrigerant 2 5 Charging 2 5 Waste Outlet and Water Seal 2 5 START UP OPERATION Controller Operation 3 1 Key Function 3 2 Further Information 3 3 Connections 3 4 LED 3 5 KDE PLUS Buttons 3 6 S...

Страница 4: ...re frozen products ATTENTION Merchandiser must operate for 24 hours before loading product Regularly check merchandiser temperatures Do not break the cold chain Keep products in cooler before loading...

Страница 5: ...should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory Any claim for loss or damage must be made to the carrier The c...

Страница 6: ...rsely affect performance and may damage the refrigeration system These models need clearance a minimum of 1 inch on each side and at the back of the unit This warning does not mean that Hussmann produ...

Страница 7: ...rious personal injury could occur Do not stand inside of merchandiser SHIPPING SKID Each merchandiser is shipped on a skid to protect the merchandiser s base and to make positioning the case easier Do...

Страница 8: ...der parts for the merchandiser REFRIGERATION UNIT ACCESS The lower access panel may be removed by lifting the panel straight upward and over the screws on which it is hanging The panel is installed by...

Страница 9: ...ension cord 6 Ensure that the proper electrical requirements for the equipment are supplied 7 Verify field electrical connections are tight 8 Verify all electrical wiring is secured and clear of any s...

Страница 10: ...1 6 INSTALLATION P N 3104942_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com NOTES...

Страница 11: ...voids the warranty Do not use an extension cord Never plug in more than one merchandiser per electrical circuit Always use a dedicated circuit with the amperage stated on the unit Plug into an outlet...

Страница 12: ...TION P N 3104942_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com REFRIGERATION SYSTEM Views below show slide out refrigeration system Pull out the condensing unit where the label i...

Страница 13: ...equipment Failure to follow instructions can result in an explosion death injury and property damage If a leak is detected follow store safety procedures It is the store s responsibility to have a wri...

Страница 14: ...sed to charge the system The charge amount is shown on the serial plate Only R 290 grade refrigerant can be used Standard propane does not meet the purity moisture content of R 290 and therefore canno...

Страница 15: ...vice tubes before brazing them shut Remove all service ports If a Schrader valve is used on the compressor service tube it must be removed and the previous steps followed in order to braze the service...

Страница 16: ...2 6 STARTUP OPERATION P N 3104942_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com NOTES...

Страница 17: ...y also cycle evaporator fan s on and off determined by the Set Point and Differential temperatures a The Set Point is the adjustable preprogrammed temperature b The Differential is the non adjustable...

Страница 18: ...SPDT relay 8 4 A max 250Va OUT4 1 SPST relay 8 4 A max 250Va OC Open Collector Output OC 1 multifunctional output 12Vc 20mA MECHANICAL CHARACTERISTICS Dimensions Terminals Connectors Humidity TTL for...

Страница 19: ...KDEPlus or KDWPlus external keyboard or ECPlus echo module 3 LINE These are power supply terminals 19 18 PB1 probe connection 4 OUT2 Shared Terminal 21 20 PB2 probe connection 5 N O OUT2 23 22 PB3 pro...

Страница 20: ...rmanently on Defrost active Blinking Activated manually or from Digital Input OFF otherwise 3 Fans Permanently on Fans active OFF otherwise 4 Reduced SET Economy Permanently on Energy Saving active Bl...

Страница 21: ...and released Press for at least 5 secs Start up 1 Scrolls through menu items Decreases values Activates the Manual Defrost function from outside menus 2 Scrolls through menu items Decreases values Fu...

Страница 22: ...LINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 GND D GND D OC 12V TTL OPTIONAL SENSOR TEMP DEFROST ORANGE 12V D GND KEYB 15 cm MAX NEUTRO NEUTRO PB1 PB2 SENSOR...

Страница 23: ...peratures should be measured at the center of the discharge honeycomb Defrosts are time initiated and temperature terminated The defrost setting is factory set as shown above To ensure a thorough defr...

Страница 24: ...OCKING Product should NOT be placed inside the merchandisers until merchandisers are at proper operating temperature Allow merchandiser 24 hours to operate before loading product Proper rotation of pr...

Страница 25: ...pty into an evaporation pan that will overflow if too much water is introduced during cleaning Do Use Remove the product and all loose debris to avoid clogging the waste outlet Store product in a refr...

Страница 26: ...duct from the merchandiser and place in cooler Always disconnect electrical power before cleaning 1 Place a small screw driver between the front grille and step pan Gently lift the step pan s front li...

Страница 27: ...to remove dirt and debris Do not bend coil fins Always wear gloves and protective eye wear when cleaning near sharp coil fins and dust particles CLEANING EVAPORATION PAN The condensate water outlet f...

Страница 28: ...unit Heat and air registers fans and doors etc x Check for water leaks x Clean evaporator coil s and fan blade s Do not use an acid base cleaner Rinse off any cleaner residue x Clean discharge air hon...

Страница 29: ...Turn off power to the merchandiser 2 Make sure there is no voltage in the refrigerator Remove front grille to have acess to the machine compartment 3 Remove condensing unit screws Fig A 4 Slide out th...

Страница 30: ...5 Sliding out the condensing unit Fig B Be careful using the condesing unit plate to pull out the condensing unit Make sure do not stress other parts 6 Disconnect condenser motor harness 7 Remove hexa...

Страница 31: ...here is no voltage in the refrigerator 3 Remove step shelf in order to access the evaporator 4 Disconnect evaporator fan motor harness for each motor 5 Remove screws 2 on each side total of 4 to remov...

Страница 32: ...information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2...

Отзывы: