background image

7 of 9

P/N 0486352_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

4

3

4

4

4

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and Light Circuits for 
 
Four Rows of Shelves

4 ft case

Connector

4

3

4

4

4

B

W

Connector

6 ft or 8 ft case

12 ft case

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

4

3

4

4

4

B

W

BL

BL

R

R

BL

R

BL

W

W

R

B

R

BL

BL

R

3

B

BL

BL

BL

BL

R

R

R

R

Optional Shelf Lighting

Fluorescent Fixtures

Содержание M4NX-GEP

Страница 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0461805 Fan Blade FB 4780446 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0461805...

Страница 2: ...Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point...

Страница 3: ...nit Sizing F 26 24 Btu hr ft Unlit Shelves M4NX GEP Parallel Conventional UNLIT 1045 1155 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST D...

Страница 4: ...59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1 53 2...

Страница 5: ...lay Area 3 Sq Ft Ft 3 69 ft2 ft 1 13 m2 m Shelf Area 4 Sq Ft Ft 5 60 ft2 ft 1 71 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated V...

Страница 6: ...B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded...

Страница 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Страница 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Страница 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Отзывы: