PRODUCT INSTALLATION MANUAL
KH14 SELF SERVE HOT FOOD
_________________________________________________________________________________________________________________________
Page 14
Hussmann
Six Monthly Maintenance
A thorough cleaning and maintenance check should be carried out on a six monthly basis by qualified and approved
refrigeration and electrical engineers. The following procedures should be undertaken as a minimum.
CAUTION
Cases should be electrically isolated
before carrying out any work that may
affect or expose electrical components.
1. Remove and clean the pan decks.
2. Remove any foreign material from the base of the case.
3. Check that all case panels, glass and trims are secure and undamaged.
4. Check for rust or paint damage.
5. Clean the air grilles on the cases.
6. Ensure all cable connections, including screw terminals, earth leads and straps, are secure.
7. Ensure insulation to all electrical components, including fan, (if any) controls, earth terminals and lights, are sound.
8. Carry out electrical safety tests, including earth continuity and insulation resistance.
9. Ensure that the correct fuse (circuit breaker) rating and type is fitted for all circuits.
With case power turned on:
10. Check that all lights and controls are working correctly.
11. Ensure light RCDs (if fitted) are working.
Operation Servicing
No servicing of Hussmann cases, is to be undertaken by store staff. Please contact your service contractor for all
maintenance queries.