Hussmann ISLA IM-FH Скачать руководство пользователя страница 22

16

 

PN_3034423_C                

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com

HUSSMANN Tech Support: 866-785-8499                    HATCO TECH SUPPORT:  800-558-0607

continued on next page...

®

Æ

19

Troubleshooting Guide (Cold Case)

Problem

Possible Cause

Possible Solution

Case temperature is 
too warm.

Ambient conditions may 
be affecting the case 
operation.  

Check case position in store. Is the case located near an 
open door, window, electric fan or air conditioning vent that 
may cause air currents? Case must be located minimum 
15 Ft away from doors or windows. Cases are designed to 

operate at 55% Relative humidity and a temperature of 75°F.

Discharge air temp is out 
of spec.

Check evaporator fan operation. Check electrical connections 
and input voltage.

Fans are installed backwards. Check airflow direction.

Fan blades are installed incorrectly. Make sure fan blades 

have correct pitch and are per specification. 

Check to see that fan plenum is installed correctly. It should 
not have any gaps.

Check suction pressure and insure that it meets factory 

specifications.

Place prepackaged hot food in case.

Case is in defrost.     

Check defrost settings. See Technical Specifications section. 

Product load may be over 

its limits blocking airflow. 

Redistribute product so it does not exceed load level. There 
is a sticker on the inside of the case indicating what the 
maximum load line is.

Coil is freezing over.

Return air is blocked, make sure debris is not blocking the 
intake section.

Coil close-offs are not installed. Inspect coil to make sure 
these parts are on the case.

Condensing coil or 
evaporator coil is clogged 
or dirty.

Clean coil.

Case temperature is 
too cold.

The t-stat temp is set too 
low.                 

Check settings. See Technical Specifications section.

Ambient conditions may 
be affecting the case 
operation.

Check case position in store. Is the case located near an 
open door, window, electric fan or air conditioning vent that 
may cause air currents? Case must be located minimum 
15 Ft away from doors or windows. Cases are designed to 

operate at 55% Relative humidity and a temperature of 75°F.

Inadequate  air  circulation.                                                                          Check if air sweep fans are functioning, check electrical 

connections.

There is not enough heat 

provided in the airflow.

Check if air sweep heater is functioning, check electrical 
connections.

There are glass gaps on 
the side of the case.

See glass adjustment section.

Glass is not completely 
shut.

Close glass correctly.

Содержание ISLA IM-FH

Страница 1: ...lation Operation Manual Shipped with Technical Data Sheets MANUAL I O ISLA COUNTER CASES ISLA Food Counters IM FR Refrigerated Counters IM FH Hot Counters IM FS Soup Counters P N P N 3034423_C January...

Страница 2: ...tions which if not avoided could result in damage to equipment The information contained in this document is the property of Hussmann Corporation and shall not be used in whole or in part without writ...

Страница 3: ...r 1 Installation 4 Exterior Loading 4 Bumper Installation 5 Waste Outlet and P Trap 6 Refrigerant Type 6 Piping 6 Control Settings 6 Evaporation Fans 6 Electrical 8 Wiring Color Code 8 Electrical Circ...

Страница 4: ...tion within 15 days and retain all packaging The carrier will supply inspection report and required claim forms Shortages Check your shipment for any possible shortages of material If a shortage shoul...

Страница 5: ...t safety standards or requirements As clarified by the California State government Proposition 65 can be considered more of a right to know law than a pure product safety law When used as designed Hus...

Страница 6: ......

Страница 7: ...WELL DATA AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS 240 1 5 1200 240 1 7 5 1800 240 1 10 2400 240 1 12 5 3000 240 1 15 3600 3 2 5 1200 5 0 1200 4 3 7 5 1800 7 5 1800 5 4 10 2400 10 0 2400...

Страница 8: ...12 10 2X 25 1 6015 OVERHEAD HEATER DATA AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS 3 94 945 5 65 1355 8 33 2000 10 15 2435 11 75 2820 3 2 3 94 945 4 3 5 65 1355 5 4 5 65 1355 6 5 8 33 200...

Страница 9: ...19 0 07 7 5 N A N A N A N A 4 3 2 0 46 36 28 0 26 0 10 10 N A N A N A N A N A 28 0 26 0 10 10 N A N A N A N A 5 4 2 0 46 36 35 0 32 0 12 12 5 N A N A N A N A N A 35 0 32 0 12 12 5 N A N A N A N A 6 5...

Страница 10: ...turally designed to support excessive external loading Do not walk on their tops This could cause serious personal injury and damage to the fixture Leveling IMPORTANT it is imperative that the ISLA FO...

Страница 11: ...1 Make sure the aluminum channel and end caps are installed Step Use silicone lubricant to help the bumperslide into the channel Step 3 Starting on one end while inserting the bumper push it up again...

Страница 12: ...insulation material such as Armstrong s Armaflex b Where condensate drains are located in dead air spaces between refrigerators or between a refrigerator and a wall provide means to prevent freezing...

Страница 13: ...al raceway or under the case Thermostatic Expansion Valve Location This device is located on the same side as the refrigeration stub A Sporlan balanced port expansion valve model is furnished as stand...

Страница 14: ...igh wattage appliances It should be wired to a dedicated circuit Electrical service Receptacles When a pplicable The receptacles located on the exterior of the merchandiser are intended for scales and...

Страница 15: ...ature requirements Critical attention must be given to the heat controls for these hot tables soup bars Both the upper and lower heat controls soup only require lower control must be adjusted to achie...

Страница 16: ...1919 Mexico 1 800 890 2900 www hussmann com 13 Startup To fill the well Turn the fill valve to open position Close the drain valve To drain the well Turn the fill valve to the closed position Open th...

Страница 17: ...D COUNTERS 14 Operation Turn power switch on Set temperature control to 7 setting Adjust as necessary Adjust overhead heater as necessary Shutting down Turn ON switch off Close fill valve Open drain v...

Страница 18: ...hould be cleaned thoroughly and frequently The interior may be cleaned with any domestic soap or detergent based cleaners Sanitizing solutions will not harm the interior bottom however these solutions...

Страница 19: ...rate a minimum of 6 hours before stocking with any product 5 When stocking never allow the product to extend beyond the recommended load limit Air discharge and return air flue must be unobstructed at...

Страница 20: ...ting The same type of lamp with protective coating must be used if replaced All lamps have the label below ENCAPSULITE SHATTERPROOF COATING SA 10645 Complies with FDA USDA OSHA Regulations for replace...

Страница 21: ...des ask for an alternative Also avoid cleaners containing quaternary salts as they also can attack stainless steel cause pitting and rusting 4 Treat your Water Though this is not always practical soft...

Страница 22: ...k defrost settings See Technical Specifications section Product load may be over its limits blocking airflow Redistribute product so it does not exceed load level There is a sticker on the inside of t...

Страница 23: ...s freezing over Return air is blocked make sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Large gap is visible o...

Страница 24: ...and call Hatco to replace if necessary Faulty control Check and call Hatco to replace if necessary Losse wiring on heater Check wiring electrical connections Temperature setting Off Increase shelf hea...

Страница 25: ...ing equipment caused by liming sediment buildup chemical attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMED...

Страница 26: ...___________ ______________________________________________________________________________________________ _______________ _____________________________________________________________________________...

Отзывы: