PW 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

2 of 4

Front

PW-8E

Waste Outlet

& Water Seal

A

Base Rail

Refrigeration

Outlet

(See Note***)

Access Area

PW-8

C

L

(See Note*

)

7

/

8

(149)

1

/

2

(89)

17

(432)

57 

5

/

8

(1464)

74 

5

/

8

(1895)

C

B

G

F

D

E

(See Note**

)

Engineering

Plan Views

Wide Island

Bulk Produce

07-2003

Dimensions are shown as inches & (mm).

4 Ft

6 Ft

8 Ft

12 Ft

General

(A)

Case Length

48 

1

/

4

(1226)

72 

1

/

4

(1835)

96 

3

/

8

(2448) 144 

1

/

2

(3670)

Maximum outside dimension of case back to front

74 

5

/

8

(1895)

74 

5

/

8

(1895)

74 

5

/

8

(1895)

74 

5

/

8

(1895)

(includes bumper)

Front of splashguard to outside edge of front base rail

7

/

8

(149)

7

/

8

(149)

7

/

8

(149)

7

/

8

(149)

Back of case to outside edge of front base rail

57 

5

/

8

(1464)

57 

5

/

8

(1464)

57 

5

/

8

(1464)

57 

5

/

8

(1464)

Front of case to outside edge of front base rail

17 (432)

17 (432)

17 (432)

17 (432)

Width of base rail

1

/

8

(54)

1

/

8

(54)

1

/

8

(54)

1

/

8

(54)

Stub-up area between front base rail and splashguard

7

/

8

(124)

7

/

8

(124)

7

/

8

(124)

7

/

8

(124)

Electrical Service 

(B)

Righthand end of case to center of farthest knockout

47 

1

/

4

(1202)

71 

1

/

4

(1810)

95 

3

/

8

(2423) 143 

5

/

8

(3650)

Length of electrical raceway

11 

7

/

8

(303)

34 

5

/

8

(878)

34 

5

/

8

(878)

34 

5

/

8

(878)

*Note:

Electrical field wiring connection point.

Waste Outlet

(C)

Right end of case to center of waste outlet

24 

1

/

8

(613)

46 

5

/

8

(613)

72 

1

/

4

(613)

72 

1

/

4

(613)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

4 (102)

4 (102)

Center of waste outlet to outside edge of front base rail

1

/

2

(89)

1

/

2

(89)

1

/

2

(89)

1

/

2

(89)

** Note:

Field installed water seal outlets, tees, and connectors are shipped with case

Drip Pipe Outlet
(D)

Left end of case to center of drip pipe outlet

20 

3

/

8

(517)

19 

1

/

2

(495)

19 

1

/

2

(495)

68 

1

/

2

(1740)

(E)

Center of waste outlet to center of drip pipe outlet

3

/

4

(95)

24 

3

/

4

(629)

51 

7

/

8

(1318)

3

/

4

(95)

(F)

Front of case to center of drip pipe outlet

24 

7

/

8

(632)

25 

7

/

8

(657)

25 

7

/

8

(657)

24 

7

/

8

(632)

Outside diameter of drip pipe lines

1

/

2

(38)

1

/

2

(38)

1

/

2

(38)

1

/

2

(38)

***Note:

Field drip pipe connection point.

Refrigeration Outlet

(G)

Righthand end of case to center of refrigeration outlet

9 (230)

9 (230)

9 (230)

9 (230)

Center of refrigeration outlet to outside edge
of front base rail

1

/

2

(89)

1

/

2

(89)

1

/

2

(89)

1

/

2

(89)

Содержание Impact PW 12

Страница 1: ...ription Wiring Item FAN ASSEMBLIES AND THERMOSTATS A 0378349 Fan Motor Evaporator 1 0142780 Fan Blade Embossing toward motor We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped ...

Страница 2: ... Righthand end of case to center of farthest knockout 47 1 4 1202 71 1 4 1810 95 3 8 2423 143 5 8 3650 Length of electrical raceway 11 7 8 303 34 5 8 878 34 5 8 878 34 5 8 878 Note Electrical field wiring connection point Waste Outlet C Right end of case to center of waste outlet 24 1 8 613 46 5 8 613 72 1 4 613 72 1 4 613 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 4 102 4...

Страница 3: ...art to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 11 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb PW PW 6 8 12 4 6 8 12E 4 ft 1 9 2 3 6 ft 1 9 2 3 8 ft 2 4 2 8 12 ft 3 7 4 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End Partition in 1 1 2 HUSSMANN CORPORATION B...

Страница 4: ...0 94 1 41 70 70 140 210 Min Circuit Ampacity With Standard Fans 120V 60Hz 0 97 0 97 1 74 2 51 With Energy Efficient Fans 120V 60Hz 0 58 0 58 0 96 1 34 With Export Fans 230V 50 Hz 0 45 0 45 0 70 0 95 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting Optional Lighting Optional Shelf Lighting None None None 120V POWER 120V NEUTRAL Fan ...