background image

4 of 7

M3G 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Electrical Data

8 ft

12 ft

Number of Fans – 9W

2

3

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.40

2.10

105

160

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50Hz)  

0.76

1.14

114

171

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz) 

1.60

2.30

With Energy Efficient Fans (120V 60Hz)

0.96

1.34

With Export Fans (230V 50Hz) 

0.96

1.34

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Standard Lighting

8 ft

12 ft

8 ft

12 ft

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Row Canopy 

1.02

1.54

118

170 

2 Row Canopy and 1 Row Rail

1.53

2.31

177

255

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

Impact  

M3G

Meat and Delicatessen
Precut and Packaged Produce

Содержание Impact M3G

Страница 1: ...047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Descripti...

Страница 2: ...ut 88 3 8 2245 136 1 2 3467 Back outside of case to center of knockout 30 1 2 775 30 1 2 775 Length of electrical raceway 34 1 2 778 34 1 2 778 Waste Outlet C Left hand end of case to the center of wa...

Страница 3: ...ft M3G M3GE Parallel 985 935 Conventional 1060 1020 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M3G M3GE Frequency hr 6 8 Defrost Water lb ft day 7 7...

Страница 4: ...th Standard Fans 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER...

Страница 7: ...he shelf configuration of this merchandiser is critical 2 Shelf Configuration for M3 M3E Top shelf must be 16 inches wide and placed at a 0 angle Second shelf may be either 16 or 18 inches wide and it...

Отзывы: