background image

5 of 7

P/N 0378417C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Defrost

Termination

Thermostat

Refrigeration

Thermostat

Dark Blue

3

To
Condensing
Unit

}

Light Blue

2

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Fan  Wiring

Offtime Defrost

2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

=  Case G

ROUND

Connector

Connector

G

Connector

Connector

Connector

Connector

Connector

Optional Shelf Harness and Light Circuits for
One Row of Shelves

120 V

Power

B

W

G

B

BL

BL

BL

G

G

R

R

BL

BL G

W

BL

Shelf Harness

Shelf Light Circuits

BL

G

R

5

4

W

BL

R

5

BL

R

G

G

R

R

R

G

Shelf Lighting

G

G

R

BL

5

BL

Connector

Connector

B

Содержание Impact M3

Страница 1: ...0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Descrip...

Страница 2: ...ut 30 1 2 775 30 1 2 775 Length of electrical raceway 34 1 2 778 34 1 2 778 Waste Outlet C Left hand end of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 D Right hand end of case to the c...

Страница 3: ...M3E Parallel 1120 1055 Conventional 1205 1155 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M3 M3E Frequency hr 6 6 Defrost Water lb ft day 7 7 15 based...

Страница 4: ...z 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER...

Страница 7: ...he shelf configuration of this merchandiser is critical 2 Shelf Configuration for M3 M3E Top shelf must be 16 inches wide and placed at a 0 angle Second shelf may be either 16 or 18 inches wide and it...

Отзывы: