background image

6 of 7

M2GE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Standard Lighting 1 Row Canopy or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Row Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

BL

R

R

BL

BL

4

5

5

R

R

R

5

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Optional  Lighting  3 Row Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

W

B

BL

R

R

BL

BL

4

5

5

5

R

R

5

R

5

Содержание IMPACT M2GE

Страница 1: ...able 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with lik...

Страница 2: ...f electrical raceway 34 1 2 878 34 1 2 878 Waste Outlet C Left hand end of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 D Right hand end of case to the center of waste outlet 24 1 8 613...

Страница 3: ...l 915 Conventional 985 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M2GE Frequency hr 6 Defrost Water lb ft day 6 15 based on case configuration and pro...

Страница 4: ...icient Fans 120V 60Hz 0 72 0 98 With Export Fans 230V 50Hz 0 76 1 04 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...GE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL...

Страница 7: ...N Bridgeton MO 63044 2483 U S A The shelf configuration of these merchandisers is critical Shelf Configuration for M2GE Top shelf must be 14 inches wide and placed at a 45 angle These shelf positions...

Отзывы: