background image

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

LNM

Discharge Air (°F)

26

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/ft*

LNM

Parallel

340

Conventional

360

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

LNM

Frequency (hr)

24

Defrost Water

(lb/ft/day)

1.0

(± 15% 

based on case configuration and product

loading).

LNM

G

AS OR

E

LECTRIC

Not Recommended

O

FFTIME

Temp Term (°F)

43

Failsafe Minutes

90

Standard Defrost Thermostat 

Close on rise: close 43°F  —  open 33°F 

CONVENTIONALCONTROLS

LNM

Low Pressure Backup Control
CI/CO 

**

12°F / 2°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

Not Recommended

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

5

/

8

Estimated Charge (lb)***

LNM

8 ft 

1.7

12 ft 

2.6

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length Added to Lineup by:
Each End/Partition (in.)

1

/

2

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

3 of 5

P/N 0402761B

FAN

LNM 

32

 3/8 (824)

39

 (991)

45

 3/4 (1161)

41

 5/8 (1057)

5

 (127)

35 

1/2

(902)

32

1/2

(825) 

15

(381)

(178)

COIL

ELEVATED 1.5 in.

Effective  

04/13/98

19

 1/4 (489)

33

 3/8 (848)

35

 7/8 (911)

Impact  

LNM

Medium Temperature Food

Single Level Narrow Island Display

Dimensions shown in inches & (mm).

NOTE:

The bumpers are 4 inches wide.  The center of the top

bumper is 30 inches from the floor and the center of the bottom

bumper is 8 

1

/

4

inches from the floor.

NSF Certification

These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF

®

) Standard #7 requirements.

Отзывы: