REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 75
°
F and
55% R.H.
LNM
Discharge Air (°F)
26
Evaporator (°F)
21
Unit Sizing (°F)
19
Btu/hr/ft*
LNM
Parallel
340
Conventional
360
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
LNM
Frequency (hr)
24
Defrost Water
(lb/ft/day)
1.0
(± 15%
based on case configuration and product
loading).
LNM
G
AS OR
E
LECTRIC
Not Recommended
O
FFTIME
Temp Term (°F)
43
Failsafe Minutes
90
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONALCONTROLS
LNM
Low Pressure Backup Control
CI/CO
**
12°F / 2°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)
Not Recommended
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
5
/
8
Estimated Charge (lb)***
LNM
8 ft
1.7
12 ft
2.6
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by:
Each End/Partition (in.)
1
1
/
2
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
3 of 5
P/N 0402761B
FAN
LNM
32
3/8 (824)
39
(991)
45
3/4 (1161)
41
5/8 (1057)
5
(127)
35
1/2
(902)
32
1/2
(825)
15
(381)
7
(178)
COIL
ELEVATED 1.5 in.
Effective
04/13/98
19
1/4 (489)
33
3/8 (848)
35
7/8 (911)
Impact
LNM
Medium Temperature Food
Single Level Narrow Island Display
Dimensions shown in inches & (mm).
NOTE:
The bumpers are 4 inches wide. The center of the top
bumper is 30 inches from the floor and the center of the bottom
bumper is 8
1
/
4
inches from the floor.
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF
®
) Standard #7 requirements.