Technical Data Sheet
2 of 7
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Access Area
(Gray)
LG
5
(127)
Front
Waste Outlet
5
9/16
(141)
Refrig. Outlet
Water Seal
Electrical
B a s e R a i l
A
B
C
2
7/8
(98)
(See Note *)
43
(1092)
29
5/8
(753)
33
(838)
30
9/16
(776)
38
7/8
(987)
36
1/4
(921)
Engineering
Plan Views
Dimensions shown as inches & (mm).
8 ft
12 ft
General
(A)
Case Length
(without ends or partitions)
96
1
/
4
(2445)
144
1
/
2
(3670)
(Each end and insulated partition adds 2 in. (51 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper)
43 (1092)
43 (1092)
Back of case to front of splashguard
38
7
/
8
(987)
38
7
/
8
(987)
Back of case to O/S edge of front base rail
29
5
/
8
(753)
29
5
/
8
(753)
Width of base rail
2
1
/
8
(54)
2
1
/
8
(54)
Stub-up area (gray) between base rail and splashguard
7
5
/
8
(194)
7
5
/
8
(194)
Electrical Service
(Electrical Field Wiring connection point)
RH End of case to center of nearest knockout
5 (127)
5 (127)
Back O/S of case to center of knockout
36
1
/
4
(921)
36
1
/
4
(921)
Waste Outlets
(B)
RH End of case to the center of waste outlet
58
1
/
4
(1480)
67
7
/
8
(1724)
LHEnd of case to center of waste outlet
38 (965)
76
5
/
8
(1946)
Back O/S of case to center of waste outlet
33 (838)
33 (838)
Water Seal
Edge of water seal to center of waste outlet
11 (279)
11 (279)
O/S diameter of drip pipe lines
1
1
/
2
(38)
1
1
/
2
(38)
Note*: Field installed water seal outlet, tees and connectors are shipped with case.
Refrigeration Outlet
RH end of case to center of RH refrigeration outlet
5
9
/
16
(141)
5
9
/
16
(141)
(C)
LH end of case to center of LH refrigeration outlet
88
3
/
8
(2245)
138
7
/
8
(3527)
Back O/S of case to center of refrigeration outlet
30
9
/
16
(776)
30
9
/
16
(776)
Low Temperature
Single Deck Wall Models