HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P2X-E

Technical Data Sheet

Defrost 

Termination 

Thermostat

Refrigeration 

Thermostat

Dark Blue

3

To 
Condensing 
Unit

}

Light Blue

2

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

5

5

4

4

4

5

5

5

5

5

5

5

Optional 

Two Row 

Canopy

Optional 

Three Row 

Canopy

Connector

5

BL

W

BL

W

G

R

BL

W

B

R

R

R

BL

BL

R

BL

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

 

 

                                      3 Row Canopy

5

4

5

5

Connector

W

B

BL

BL

R

BL

R

R

R

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Содержание Impact Excel P2X-E

Страница 1: ...rost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Ballast Electronic 4 0480130 2 lamps BA 4481676 0480131 3 lamps BA 4481654 04...

Страница 2: ...rnal legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4...

Страница 3: ...efrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lbs P2X E 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types actu...

Страница 4: ...Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51...

Страница 5: ...3 m ARI Total Display Area 3 Sq Ft Ft 3 39 ft2 ft 1 03 m2 m Shelf Area 4 Sq Ft Ft 3 87 ft2 ft 1 18 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2...

Страница 6: ...5 5 5 Optional Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R...

Страница 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Страница 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and...

Страница 9: ...L R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Отзывы:

Похожие инструкции для Impact Excel P2X-E