background image

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

600 (272)

800 (363)

1000 (454)

1300 (590)

75 (34)

5

Actual weights will vary according to optional kits included.

P/N 0463864_D

5 of 8

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

M3X-GE

Meat, Delicatessen 

Pre-cut and Packaged Produce

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

6.98 ft

3

/ft  (0.65 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

6.02 ft

/ft  (0.56 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

3.49 ft

2

/ft  (1.06 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

5.35 ft

2

/ft  (1.63 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (1) row of 16-inch shelf and (1) row of 

18-inch shelf.

eparately from fans.

Содержание Impact Excel M3X-GE

Страница 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Страница 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Страница 3: ...Temperature Pressure Chart to deter mine PSIG conversions Estimated Charge lb M3X GE 4 ft 1 4 6 ft 1 9 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types Actual refrigerant charge may va...

Страница 4: ...1 19 230V 50Hz Export 0 58 0 76 0 96 1 34 120V 60Hz Energy Efficient 0 50 0 58 0 80 1 10 230V 60Hz Energy Efficient 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Cu...

Страница 5: ...56 m3 m ARI Total Display Area 3 Sq Ft Ft 3 49 ft2 ft 1 06 m2 m Shelf Area 4 Sq Ft Ft 5 35 ft2 ft 1 63 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...ow Canopy 3 Row Canopy B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchand...

Страница 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Страница 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Отзывы: