background image

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

M3X-EP

U

NLIT

L

IT

Discharge Air °F

31

29

Evaporator °F

28

26

Unit Sizing °F

26

24

Btu/hr/ft — Unlit Shelves

M3X-EP

‡‡

Parallel

Conventional

U

NLIT

930

1010

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

Frequency Hrs

6

Defrost Water (lb/ft/day)

8

(± 15% based on case configuration and

product loading).

O

FFTIME

M3X-EP

Time (minutes) 

30

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

M3X-EP

19°F / 9°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to

determine PSIG conversions.

Estimated Charge (lb)**

M3X-EP

4 ft

1.6

6 ft

2.2

8 ft

3.1

12 ft

4.5

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 8

P/N 0463875_D

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

74 

3

/

8

 

(1890)

31 

5

/

(804)

3

/

4  

(120)

30 

1

/

4   

(768)

42 

 

(1064)

33 

1

/

(851)

26 

1

/

(665)

Refrigeration 

Outlet

30 

1

/

4

 

(768)

42 

1

/

2

 

 

(1080)

34 

5

/

8

 

(878)

36 

1

/

2

 

(927)

FAN

L

28 

5

/

8

 

(727)

3 In. 

(77 mm) 

Required 

Air Gap

1

/

(183)

31

 

(788)

15

 

(381)

16 

1

/

4

 

(413)

Electrical 

Case to Case 

Connections

17 

1

/

(436)

Dimensions shown as inches and (mm).

Multi-deck, 3 Display Levels

Impact  

Excel

M3X-EP

Meat, Delicatessen 

Pre-cut and Packaged Produce

M3X-EP

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Содержание Impact Excel M3X-EP

Страница 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780...

Страница 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Страница 3: ...Chart to determine PSIG conversions Estimated Charge lb M3X EP 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately ha...

Страница 4: ...0 86 1 19 230V 50Hz Export 0 58 0 76 0 96 1 34 120V 60Hz Energy Efficient 0 50 0 58 0 80 1 10 230V 60Hz Energy Efficient 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Ov...

Страница 5: ...56 m3 m ARI Total Display Area 3 Sq Ft Ft 3 49 ft2 ft 1 06 m2 m Shelf Area 4 Sq Ft Ft 5 37 ft2 ft 1 64 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...o Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 R...

Страница 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Страница 8: ...6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Отзывы: