background image

M3X-E 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

8 of 8

4 ft case

6 ft or 8 ft case

12 ft case

R

BL

R

BL

7

7

R

BL

6

B

W

W

BL

R

G

Connector

Connector

B

W

B

W

B

W

R

BL

R

BL

7

7

R

BL

R

BL

R

BL

7

7

R

BL

R

BL

BL

BL

(TYP)

Shelf Light

Plug & Receptacle

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and LED Light Circuits for 
 
 
Two Rows of Shelves

R

R

B

Optional Shelf Lighting
LED Fixtures

Содержание Impact Excel M3X-E

Страница 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Страница 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Страница 3: ...ion 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb M3X E 4 ft 1 4 6 ft 1 9 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types Actual refrigerant c...

Страница 4: ...86 1 19 230V 50Hz Export 0 58 0 76 0 96 1 34 120V 60Hz Energy Efficient 0 50 0 58 0 80 1 10 230V 60Hz Energy Efficient 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Ove...

Страница 5: ...56 m3 m ARI Total Display Area 3 Sq Ft Ft 3 49 ft2 ft 1 06 m2 m Shelf Area 4 Sq Ft Ft 5 37 ft2 ft 1 64 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...BL R BL R R R Optional Lighting 1 Row Rail B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components...

Страница 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Страница 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and...

Отзывы: