Engineering

Plan Views

Dimensions shown as in. and (mm).

Convertible

09-2005

4 ft

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.) Optional view end with bumper adds 3 

3

/

4

in. [95 mm]).

Maximum O/S dimension of case back to front 

(includes bumper)

42 (1064)

42 (1064)

42 (1064)

42  (1064)

Back of case to front of splashguard

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

33 

1

/

(851)

Back of case to O/S edge of front leg

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

30 

1

/

(768)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

Back of case to center of stub up area

24 (612)

24 (612)

24 (612)

24 (612)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

31 

5

/

(804)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

26 

1

/

(665)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

3

/

(120)

Splashguard

31 

5

/

(804)

42

 

(1064)

A

41 

1

/

(1054)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Waste Outlet

Waste Outlet

FRONT

26 

1

/

(665)

B

D

8

 

(203)

1

/

(115)

12 

1

/

(307)

41 

1

/

(1054)

43 

7

/

(1114)

C

Wireway

3

/

(120)

26 

1

/

(673)

1

/

(108)

24

 

(612)

33 

1

/

(851)

Electrical 
Field 
Connection

30 

1

/

(768)

C5X

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Содержание impact Excel C5X-E

Страница 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Страница 2: ...24 612 24 612 24 612 24 612 Length of electrical wireway 26 1 2 673 26 1 2 673 26 1 2 673 26 1 2 673 C RH End of case to LH end of wireway 42 1 8 1070 66 1 8 1680 90 1 8 2289 138 1 4 3511 Waste Outlet...

Страница 3: ...4 F 17 F 7 F 17 F 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C5X E 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5...

Страница 4: ...Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8...

Страница 5: ...ft 0 87 m3 m ARI Total Display Area 3 Sq Ft Ft 4 44 ft2 ft 1 35 m2 m Shelf Area 4 Sq Ft Ft 9 88 ft2 ft 3 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Leng...

Страница 6: ...tor 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R...

Страница 7: ...components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Five Rows of Shelves 4 ft...

Страница 8: ...R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING...

Отзывы: