background image

4 of 8

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C3LGE 

Data Sheet

Impact 

C3LGE

Delicatessen/Dairy

Precut & Packaged Produce

Electrical Data

8 Ft

12 Ft

Number of Fans — 9W

2

3

Amperes

Watts

Merchandiser

8 Ft

12 Ft

8 Ft

12 Ft

Fans

Standard (120V 60Hz)

1.40

2.10

100

150

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50Hz)

0.76

1.14

114

171

Constant on Anti-sweat Heaters

NA

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

1.60

2.30

With Energy Efficient Fans (120V 60Hz)

0.96

1.34

Export (230V 50Hz)

0.96

1.34

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost

NA

Standard Lighting

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Rail

1.02

1.54

118

170

2 Rows Canopy

1.02

1.54

118

170

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

Содержание IMPACT Excel C3LGE

Страница 1: ...ing Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optio...

Страница 2: ...rthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of wast...

Страница 3: ...tion and product loading OFFTIME C3LGE Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pre...

Страница 4: ...eaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 60 2 30 With Energy Efficient Fans 120V 60Hz 0 96 1 34 Export 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum O...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND Connector Connector G Connector Connector Connector Co...

Страница 6: ...AND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 Standard Lighting 1 Row Canopy or Optional 1 Row Rail Light Circuits Optional Lighting 2 Rows Canopy WARNING All components must have...

Страница 7: ...e of peg shelves is NOT recommended on C3LGE cases Depth and angle requirements are listed below Top Shelf Shelf Depth Shelf Angle 12 inches 0 10 15 30 45 14 inches 30 45 Second Shelf Shelf Depth Shel...

Страница 8: ...ng case of the merchandiser To access the ballast 1 Remove screws from the front lip of light tray flange covering the bottom edge of the canopy Also remove screws located near the middle rear of ligh...

Отзывы: