background image

6 of 10

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C2X-XLEP

Technical Data Sheet

Refrigeration 

Thermostat

2

To 
Condensing 
Unit

}

Light Blue

1, 2 & 3 Fans

120V N

EUTRAL

B

ROWN

  B

AND

120V P

OWER

Fans

1

B

ROWN

  B

AND

 

 1 Fan 

 

 2 Fans 

 

 2 Fans 

 

 3 Fans

4 ft 
6 ft 
8 ft 

12 ft

12 ft

5

5

4

4

5

5

5

5

Optional 

Two Row 

Canopy

Connector

BL

BL

W

G

R

BL

W

R

R

R

BL

BL

R

BL

R

R

R

B

B

Orange or Tan Band

Standard Lighting 

 1 Row Canopy 

 Optional Lighting 

 2 Row Canopy

5

4

5

5

Connector

W

B

BL

BL

R

BL

R

R

R

 Optional Lighting 

 1 Row Rail

B

4 ft

6 ft or 8 ft

12 ft

4 ft

6 ft or 8 ft

12 ft

 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Fan Wiring
Offtime Defrost

Light Circuits

Содержание impact Excel C2X-XLEP

Страница 1: ...Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B Optional Adjustable...

Страница 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Страница 3: ...ST DATA C2X XLEP Frequency hr 8 Defrost Water lb ft day 7 15 based on case configuration and product loading OFFTIME C2X XLEP Time minutes 30 ELECTRIC OR GAS Not Recommended CONVENTIONAL CONTROLS Low...

Страница 4: ...ficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 12 18 24 36 S...

Страница 5: ...Total Display Area 3 Sq Ft Ft 3 50 ft2 ft 1 07 m2 m Shelf Area 4 Sq Ft Ft 6 38 ft2 ft 1 94 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Ref...

Страница 6: ...r BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 f...

Страница 7: ...echanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 5 5 5 B W 6 ft...

Страница 8: ...L R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Страница 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth...

Страница 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...

Отзывы: