background image

4 of 7

E2V  

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact

Elite

E2V

Delicatessen
Precut & Packaged Produce

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans — 7W

1

2

2

3

Number of Fans — 7W (Export)

1

2

2

3

(Export: 230V 50 hz shown)

Amperes

Watts

Merchandiser

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Fans

Standard (120V 60Hz)

0.50

1.00

1.00

1.50

36

78

78

117

Energy Efficient (120V 60 Hz)

0.26

0.52

0.52

0.78

18

36

36

54

Export (230V 50Hz)

0.28

0.56

0.56

0.84

44

89

89

132

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz) 

0.70

1.20

1.20

1.70

With Energy Efficient Fans (120V 60 Hz)

0.46

0.72

0.72

0.98

With Export Fans (230V 50Hz) 

0.48

0.76

0.76

1.04

Maximum Over Current Protection

20

20

20

20

Export (230V 50Hz)

15

15

15

15

Electric Defrost Heaters (208V 1Ph)

NA

Standard Lighting

2 Rows Canopy

0.51

1.01

1.01

1.52

66

122

122

183

Optional Lighting

1 Row Rail Lights

0.51

0.51

0.51

0.76

62

62

62

96

1 Row Ledge Lights

0.51

0.51

0.51

0.76

62

62

62

96

Optional Shelf Lighting

1 Row of Shelves

0.51

0.51

0.51

0.76

62

62

62

96

2 Rows of Shelves

0.51

1.01

1.01

1.52

66

122

122

183

3 Rows of Shelves

0.76

1.53

1.53

2.28

92

184

184

274

Содержание IMPACT Elite E2V

Страница 1: ...g Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN...

Страница 2: ...l 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B Length of electrical raceway 18 3 8 467 18 3 8 467 37 940 37 940 C RH End of case to center of f...

Страница 3: ...F 18 21 Unit Sizing F 16 19 Btu hr ft Parallel 945 920 Conventional 1030 1000 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency hr 6 Defrost Water...

Страница 4: ...Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export Fans 230V 50Hz 0 48 0 76 0...

Страница 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Страница 6: ...nts in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Страница 7: ...locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal...

Отзывы: