background image

12 

1

/

(308)

 

FAN

Refrigeration 

Outlet

Electrical

FA

N

DA

O

COIL

33 

5

/

(854)

 

3

/

8 (308)

 

22 

1

/

(572)

 

11 

3

/

8 (289)

 

5

/

(92)

 

13 

3

/

(349)

 

34

 

(864)

 

25 

5

/

8 (651)

 

28 

3

/

4 (730)

 

33 

3

/

8 (849)

 

44 

5

/

8 (1133)

 

46

 (1168)

 

18 

1

/

(470)

 

Impact  

EDS1

Delicatessen

Dimensions shown in inches & (mm).

REFRIGERATION DATA

Note: 

This data is based on store

temperature and humidity that does not
exceed 75

°

F and 55% R.H.

EDS1

Discharge Air (°F)

24

Evaporator(°F)

14

Unit Sizing (°F)

12

Btu/hr/ft*

EDS1

Parallel

390

Conventional

420

DEFROST DATA

EDS1

Frequency (hr)

12

Defrost Water (lb/ft/day)

0.20

(± 15% 

based on case configuration and

product loading).

O

FFTIME

EDS1

Temp Term (°F)

43

°

F

Failsafe minutes

90

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat

Close on rise:     close 43°F – open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

EDS1

CI/CO*

7°F / -3°F

Indoor Unit Only, Pressure  Defrost
Termination*

43°F

*Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

EDS1

Merchandiser Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

5

/

8

Estimated Charge (lb)**
4 ft

1.0

8 ft 

1.5

12 ft 

2.0

**This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.

Length Added to Lineup by:
Each 

Plastic

End w/ 

Bumper 

(in.)

1

/

2

Each End/Partition (in.)

1

/

2

Self Service Glass, 1 Display Level

3 of 6

P/N 0431326_A

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF ®) Standard #7 requirements. 

EDS1

Отзывы: