12
1
/
8
(308)
FAN
Refrigeration
Outlet
Electrical
FA
N
DA
O
COIL
33
5
/
8
(854)
7
3
/
8 (308)
22
1
/
2
(572)
11
3
/
8 (289)
3
5
/
8
(92)
13
3
/
4
(349)
34
(864)
25
5
/
8 (651)
28
3
/
4 (730)
33
3
/
8 (849)
44
5
/
8 (1133)
46
(1168)
18
1
/
2
(470)
Impact
EDS1
Delicatessen
Dimensions shown in inches & (mm).
REFRIGERATION DATA
Note:
This data is based on store
temperature and humidity that does not
exceed 75
°
F and 55% R.H.
EDS1
Discharge Air (°F)
24
Evaporator(°F)
14
Unit Sizing (°F)
12
Btu/hr/ft*
EDS1
Parallel
390
Conventional
420
DEFROST DATA
EDS1
Frequency (hr)
12
Defrost Water (lb/ft/day)
0.20
(± 15%
based on case configuration and
product loading).
O
FFTIME
EDS1
Temp Term (°F)
43
°
F
Failsafe minutes
90
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
EDS1
CI/CO*
7°F / -3°F
Indoor Unit Only, Pressure Defrost
Termination*
43°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
EDS1
Merchandiser Drip Pipe (in.)
1
1
/
2
Liquid Line (in.)
3
/
8
Suction Line (in.)
5
/
8
Estimated Charge (lb)**
4 ft
1.0
8 ft
1.5
12 ft
2.0
**This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.
Length Added to Lineup by:
Each
Plastic
End w/
Bumper
(in.)
3
1
/
2
Each End/Partition (in.)
1
1
/
2
Self Service Glass, 1 Display Level
3 of 6
P/N 0431326_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ®) Standard #7 requirements.
EDS1