background image

4 of 6

D5L

Data Sheet Set

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

D5L

Dairy & Delicatessen

Electrical Data

Number of Fans 

8 ft

12 ft

Refrigeration – 9W

2

3

Export – 9W

2

3

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.40

2.10

105

160

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50Hz)  

0.76

1.14

114

171

Constant On Anti-sweat Heaters

NA

NA

NA

NA

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans 

1.60

2.30

With Energy Efficient Fans 

0.96

1.34

With Export Fans (230V 50Hz) 

0.96

1.34

Maximum Over Current Protection 120V

20

20

Export (230V 50Hz)

15

15

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

NA

NA

NA

Gas Defrost Heaters (208V)

NA

NA

NA

NA

Standard Lighting

8 ft

12 ft

8 ft

12 ft

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Rows Canopy 

1.02

1.54

118

170 

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

Optional Shelf Lighting

1 Row Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

4 Rows of Shelves

2.04

3.08

236

340

Содержание IMPACT D5L

Страница 1: ...1 0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0376409 Ballast Electronic 2 lamps 4 D 0376410 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures D5L Data Sheet Set P N 0378426E NSF C...

Страница 2: ...support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 3...

Страница 3: ... Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb D5L D5LE 8 ft 2 3 2 7 12 ft 3 3 3 9 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length A...

Страница 4: ...Minimum Circuit Ampacity With Standard Fans 1 60 2 30 With Energy Efficient Fans 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 ...

Страница 5: ...ctor Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components...

Страница 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Swit...

Отзывы:

Похожие инструкции для IMPACT D5L