background image

6 of 8

D5HR Data Sheet Set

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Standard Lighting  1 Row Canopy  or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Rows Canopy

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

=  120V P

OWER

=  120V N

EUTRAL

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Optional  Lighting  3 Row Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

BL

R

R

BL

BL

4

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

W

B

BL

R

R

BL

BL

4

5

5

R

5

R

R

R

R

R

5

Содержание IMPACT D5HR

Страница 1: ...S AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0435961 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refri...

Страница 2: ...xternal support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 7 178 7 178 Electrical Service Elec...

Страница 3: ...T UNLIT SHELVES Parallel 1480 1425 Conventional 1580 1520 HUSSMANN PEG SHELVES DELI ONLY Parallel 1545 1500 Conventional 1640 1600 For all refrigeration equipment other than Hussmann use conventional...

Страница 4: ...nergy Efficient Fans 120V 60Hz 1 72 2 48 With Export Fans 230V 50Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1 NA NA NA NA Gas Defrost...

Страница 5: ...hted Shelves Note 8 Foot merchandiser has two columns of four shelves and 12 Foot merchandiser has three columns of four shelves Shelf Harness Shelf Light Circuits BL G R 5 Connector BL G R 5 Connecto...

Страница 6: ...t models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR...

Страница 7: ...ors Fully Closed Double walled telescoping doors slide both left and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Dairy Mer...

Страница 8: ...to the cooler Rear View of 12 Foot Dairy Merchandiser 23 3 4 130 1 4 37 3 4 67 1 2 79 1 2 23 3 4 D o o r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide b...

Отзывы: