D5ELE / D5EE Data Sheet Set

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Electrical Data

Number of Fans 

D5ELE D5EE

Refrigeration – 9W 

2

2

Ambient Air Wipe – 15W 

1

1

Export – 9W 

2

2

Amperes

Watts

Merchandiser

D5ELE D5EE

D5ELE D5EE

Fans (Refrigeration)

Standard (120V 60Hz)

1.40

1.40

110

110

Energy Efficient (120V 60Hz)

0.76

0.76

50

50

Export (230V 50Hz)

0.76

0.76

114

114

Fans (Ambient Air Wipe)

Standard (120V 60Hz)

0.25

0.25

22

22

Energy Efficient (120V 60Hz)

NA

NA

NA

NA

Export (230V 50Hz)

0.15

0.15

25

25

Constant On Anti-sweat Heaters

NA

NA

NA

NA

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

1.60

1.60

With Energy Efficient Fans (120V 60Hz)

0.96

0.96

With Export Fans (230V 50Hz)

0.47

0.47

Maximum Over Circuit Protection 

Standard 120V

20

20

Export (230V 50Hz)

15

15

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

NA

NA

NA

Standard Lighting

1 Row Canopy

0.51

0.51

   59         59

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.02

118

118 

2 Rows Canopy 

1.02

1.02

118

118 

2 Rows Canopy and 1 Row Rail

1.53

1.53

177

177

Optional Shelf Lighting

1 Row of Shelves

0.51

0.51

59

59

2 Rows of Shelves

1.02

1.02

118

118

3 Rows of Shelves

1.53

1.53

177

177

4 Rows of Shelves

2.04

2.04

236

236

Impact  

D5ELE / D5EE

Dairy & Delicatessen