Electrical Data

Number of Fans 

90 in.

138 in.

Refrigeration – 6W 

2

4

Refrigeration– 9W 

2

2

Amperes

Watts

Merchandiser

90 in.

138 in.

90 in. 138 in.

Fans (Refrigeration)

Standard (120V 60Hz)

1.76

2.76

128

206

Energy Efficient (120V 60Hz)

1.28

1.80

86

122

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz) 

1.96

2.96

With Energy Efficient Fans (120V 60Hz)

1.48

2.00

Maximum Over Current Protection 120V

20

20

Electric Defrost Heaters (208V 1

F

)

NA

NA

NA

NA

Standard Lighting

90 in.

138 in.

90 in. 138 in.

1 Row Canopy

1.31

1.82

99

158

Optional Lighting

2 Rows Canopy 

1.82

2.84

158

276 

Optional Shelf Lighting

1 Row Shelves

1.31

1.82

99

158

2 Rows of Shelves

2.62

3.64

198

316

Note 1:

All CW2 end compartments are equipped with Energy Efficient fan motors as standard.

Note 2:

CW2 end compartments are not available with 2 row canopy lighting due to space constraints.

Impact  

CW2U-GE

Unitized Convertible Island

Содержание IMPACT CW2U-GE

Страница 1: ...n Assembly 2 0441479 Fan Motor Standard 0377253 Fan Blade embossing away from motor C 0398558 Standard Non Adjustable 3 Defrost Thermostat D 0144732 Optional Adjustable 4 Refrigeration Thermostat Item...

Страница 2: ...58 3 16 1945 Center of waste outlet to O S edge of rear base rail 3 7 8 98 3 7 8 98 Left end of case to center of front waste outlet 38 1 8 968 38 1 8 968 Right edge of end compartment to center of w...

Страница 3: ...60 18 220 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA CW2U CW2U 90GE 138GE Frequency hr 6 6 Defrost Water lb day 72 112 15 based on case configuration...

Страница 4: ...ans 120V 60Hz 1 96 2 96 With Energy Efficient Fans 120V 60Hz 1 48 2 00 Maximum Over Current Protection 120V 20 20 Electric Defrost Heaters 208V 1F NA NA NA NA Standard Lighting 90 in 138 in 90 in 138...

Страница 5: ...rayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must...

Страница 6: ...B W BL BL 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL BL Standard Lighting 1 Row Canopy Light Circuits Optional Lighting 2 Rows Canopy WARNING All components must...

Страница 7: ...llast Ballast B B BL B B B BL B Ballast Ballast B B BL B B B BL B BACK SHELF HARNESS SHELF 1 W B R W B CANOPY LIGHT HARNESS W B G B BALLAST FEED HARNESS TO CASE RACEWAY 120V G R SHELF LIGHT HARNESS 12...

Отзывы:

Похожие инструкции для IMPACT CW2U-GE