background image

6 of 6

CW2GE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Standard Lighting  1 Row Canopy  or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Rows Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

5

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

B

AND

B

BL

R

R

BL

BL

4

5

5

R

R

R

5

Grayed components in 12 foot models only.

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

WARNING

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

Содержание IMPACT CW2-GE

Страница 1: ...698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0398558 Standard Non adjustable 2 Defrost Thermostat C 0144732 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 GE Data Sheet Set P N 0399334B NSF Cert...

Страница 2: ...2 1 8 54 2 1 8 54 2 1 8 54 Stub up area between front base rail and splashguard 7 1 4 184 7 1 4 184 7 1 4 184 Electrical Service Note Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 7 178 7 178 7 178 Right end of case to center of knockout 5 127 5 127 5 127 Length of electrical raceway 46 5 8 1184 46 5 8 1184 46 5 8 1184 Waste Outlet B LH End of...

Страница 3: ...llel 1480 Conventional 1640 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA CW2GE Frequency hr 6 Defrost Water lb ft day 10 15 based on case configuration and product loading OFFTIME CW2GE Temp Term F 48 F Failsafe minutes 45 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure ...

Страница 4: ...1 56 36 72 108 Cycling Anti sweat Heaters NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 20 2 20 3 20 With Energy Efficient Fans 120V 60Hz 0 74 1 24 1 76 Maximum Over Current Protection 120V 20 20 20 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA NA NA Standard Lighting 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft 1 Row Canopy 0 51 1 02 1 54 59 118 177 Optional Lighting 2 Rows Canopy...

Страница 5: ... Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Refrigeration Thermostat To Condensing Unit Field Installed 3 4 Dark Blue Defrost Termination Thermostat BROWN BAND Fans BROWN BAND 120V POWE...

Страница 6: ...120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS...