background image

B

D

C

E

D

A

E

E

C2SLE

Data Sheet Set

P/N 0408922

NSF

®  Certified

November, 2002

P/N 0408922

Note:

Changed items have been underlined.

Merchandisers

®

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

,

AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator
115V, 6W, CW

0142780

Fan Blade
embossing toward motor
8 in., 25°, CW

B. 0411744

Standard Non-adjustable 

(2)

disc type Defrost Thermostat

C. 0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0428002

Ballast  

1 lamp

(4)

D. 0428648

Ballast  

2 lamps

(4)

D. 0428649

Ballast  

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

Содержание Impact C2SLE

Страница 1: ...LIES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 115V 6W CW 0142780 Fan Blade embossing toward motor 8 in 25 CW B 0411744 Standard Non adjustable 2 disc type Defrost Thermostat C...

Страница 2: ...kidrail and splashguard 7 178 7 178 7 178 7 178 Electrical Service B RH end of case to the center of LH knockout 40 1 4 1022 64 1 4 1632 88 3 8 2245 136 1 2 3467 Back O S of case to center of knockout...

Страница 3: ...y 6 15 based on case configuration and product loading OFFTIME C2SLE Temp Term F 48 Failsafe min 30 Standard Defrost Thermostat Close on rise close 48 open 33 CONVENTIONALCONTROLS Low Pressure Backup...

Страница 4: ...Anti sweat Heaters NA NA NA NA NA NA NA NA Min Circuit Ampacity With Standard Fans 0 70 1 20 1 20 1 70 Energy Efficient 0 46 0 72 0 72 0 98 Export 230V 50 hz 0 48 0 76 0 76 1 04 Max Over Current Prot...

Страница 5: ...llow G Green BL Blue B Black W White WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 1 2 3 Fans Optional Shelf Harness...

Страница 6: ...BL BL 4 R 5 5 5 W 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded Grayed components in 12 ft models only R Red Y Yellow G Green BL Blue...

Страница 7: ...it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 16 in or less 45 16 in or less NOTE Shelves placed in the lower positions may...

Страница 8: ...erchandiser when facing case To access the ballast 1 Remove screws at bottom edge of the canopy and rear of the top panel 3 Remove the one piece canopy top panel by moving panel forward slightly to cl...

Отзывы: