HSD/SC-518             115 

 

 15 amp             172 

 18.3 

 

Page 5 

 
 

                

ELECTRICAL                          CAPACITY 

           

   

           Breaker           Ship           Cubic    

 

              Volts        Size             Weight          Feet     

HSD/SC-132P           115       15 amp              102 

  4.7 

HSD/SC-162P           115       15 amp              106                5.7 
HSD/SC-192P           115       15 amp              115                6.8 
HSD/SC-218P           115       15 amp              124                7.7 
 
HBD/BC-142H          115       15 amp               75                5.0 

 

HBD/BC-160H          115       15 amp               77                5.6 

 

HBD/BC-180H          115       15 amp               79               6.4 
HBD/BC-195H          115       15 amp               86                6.9 

 

HBD/BC-215H          115       15 amp               93                7.6 

 

HBD/BC-258H          115       15 amp               99                9.1    

 

HBD/BC-302H          115       15 amp             106              10.7 
 
 

 

Check the unit serial plate location on the rear of the case for the type and amount  
of refrigerant used as this is subject to change from time to time: 
 

 

                                      R-134a 

 

 

HSD/SC-190Y    Curved Glass Top        5.64oz 
HSD/SC-220Y    Curved Glass Top        6.35oz 
HSD/SC-280Y    Curved Glass Top       7.05oz 
HSD/SC-320Y    Curved Glass Top        8.11oz 
 
HSD/SC-258        Flat Top Int. Step        4.59oz 
HSD/SC-302        Flat Top Int. Step        4.71oz 
HSD/SC-358        Flat Top Int. Step        5.29oz 
HSD/SC-408        Flat Top Int. Step        6.00oz 
HSD/SC-518        Flat Top Int. Step        7.41oz 

 

 
HSD/SC-132P     Flat Top Flat Int.         3.17oz  
HSD/SC-162P     Flat Top Flat Int.         3.35oz 
HSD/SC-192P     Flat Top Flat Int.         3.53oz 
HSD/SC-218P     Flat Top Flat Int.         4.05oz 
 

 

               

 

HBD/BC-142H   Solid Top Int. Step       2.82oz        

 

HBD/BC-160H   Solid Top Int. Step       3.17oz     
HBD/BC-180H   Solid Top Int. Step       3.35oz                   
HBD/BC-195H   Solid Top Int. Step       3.53oz    
HBD/BC-215H   Solid Top Int. Step       3.70oz    
HBD/BC-258H   Solid Top Int. Step       4.76oz    
HBD/BC-302H   Solid Top Int. Step       4.94oz 
 

 

 

Содержание HBD/BC-142

Страница 1: ...s Sliding Glass Top Solid Top Freezer Cooler Chests Curved Top Y Interior Step Flat Top Interior Step Flat Top P Flat Interior Solid Top H Interior Step Hussmann Corporation 12999 St Charles Rock Road...

Страница 2: ...pacities 4 Refrigerant and Refrigerant Charges 5 Installation and Start Up Leveling Casters Baskets 6 Drain and Power Cord 7 Temperature Control and Defrosting 8 Cleaning Condenser 9 Cleaning Exterior...

Страница 3: ...remove shipping crate and examine cabinet for concealed damage If damage is found contact the delivering carrier immediately and have his agent prepare an inspection report for the purpose of filing a...

Страница 4: ...1 20 6 HSD SC 162P 33 9 21 3 36 3 28 7 16 1 20 6 HSD SC 192P 38 8 21 3 36 3 33 7 16 1 20 6 HSD SC 218P 42 5 21 3 36 3 37 4 16 1 20 6 HBD BC 142H 28 9 21 3 33 8 23 8 16 1 25 6 HBD BC 160H 31 5 21 3 33...

Страница 5: ...nge from time to time R 134a HSD SC 190Y Curved Glass Top 5 64oz HSD SC 220Y Curved Glass Top 6 35oz HSD SC 280Y Curved Glass Top 7 05oz HSD SC 320Y Curved Glass Top 8 11oz HSD SC 258 Flat Top Int Ste...

Страница 6: ...sters have a lock in place feature To activate the locking mechanism push down firmly on the plastic flange that protrudes from the caster To unlock the caster pull up on the flange The casters are of...

Страница 7: ...product loss due to overloading or malfunction of other equipment on the same circuit Use a 15 amp time delay fuse The supply circuit must conform to National and local electrical codes A wiring diagr...

Страница 8: ...refrigerator temperatures Due to the case design once an adjustment is made some time will lapse before the temperature inside the fixture reacts to the change DEFROSTING Disconnect Power Supply Befo...

Страница 9: ...NTERIOR For cleaning the interior of the liner storage area a flush out drain has been provided on the case floor to assist in getting rid of any water in the bottom of the case Disconnect the electri...

Страница 10: ...artment opening 7 Defective condenser fan motor 7 Replace High head pressure 1 Cabinet location too warm 1 Relocate cabinet remove air flow restriction 2 Defective condenser fan motor 2 Replace 3 Air...

Страница 11: ...art number is not known give a clear description of part itself and its function in the cabinet or remote unit Warranty Parts Procedure Same as items above Give original installation date of cabinet a...

Страница 12: ...iding Glass Door Lower HSD SC 408 5 HM 1005 Sliding Glass Door Lower HSD SC 518 5 HM 1006 Sliding Glass Door Lower HSD SC 190Y 5 HM 1007 Sliding Glass Door Lower HSD SC 220Y 5 HM 1008 Sliding Glass Do...

Страница 13: ...62P 192P 218P 5 HM 12007 Keyes for Lid Lock HSD SC 190Y 220Y 280Y 320Y 5 HM 12008 Keyes for Lid Lock HBD BC 142H 160H 180H 195H HBD BC 215H 258H 302H 5 HM 13001 Opt Light Fuse 2 Amp Curved Glass with...

Отзывы: