4. Air or non-condensable
gasses in system
4. Leak check, change drier,
evacuate, and recharge.
Warm storage temperatures
1. Temperature control not
set properly
1. Reset control
2. Short of refrigerant
2. Leak check, change drier,
evacuate, and recharge
3. Cabinet location too
warm
3. Relocate
4. Too much refrigerant
4. Change drier evacuate,
and recharge
5. Low voltage compressor
cycling on overload
5. Check power
6. Condenser dirty
6. Clean
7. Honeycomb iced up
7. Clean
Compressor runs
continuously product too
cold
1. Defective control
1. Replace
2. Control feeler tube not in
positive contact
2. Assure proper contact
3. Short on refrigerant
3. Leak check, change drier,
evacuate, and recharge
Compressor will not start no
noise
1. Blown fuse or breaker
1. Replace fuse or reset
breaker
2. Defective or broken
wiring
2. Repair or replace
3. Defective overload
3. Replace
4. Defective temp control
4. Replace
5. Power disconnected
5. Check service cord or
wiring connections.