background image

6 ft

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

51 

5

/

8

(1311)

51 

5

/

8

(1311)

51 

5

/

8

(1311)

(front of canopy through cooler wall not including electrical box)

Cooler wall to front of splashguard

43 

3

/

(1111)

43 

3

/

(1111)

43 

3

/

(1111)

Cooler wall to O/S edge of front rails

40 

3

/

(1035)

40 

3

/

(1035)

40 

3

/

(1035)

Distance between edges of external rails and center rails

41 

1

/

(1054)

41 

1

/

(1054)

41 

1

/

(1054)

Distance between edges of center rails

NA

NA

43 

7

/

(1114)

Distance between front rails and splashguard

3

/

4

(197)

3

/

4

(197)

3

/

4

(197)

Electrical Service             

(Electrical Field Wiring connection point located on top of case)

(B)

RH End of case to center of 4 x 4 x 2 Electrical Box

2 (51)

2 (51)

2 (51)

Back of case (cooler wall) to center of 4 x 4 x 2 Electrical Box

1

/

4

(57)

1

/

4

(57)

1

/

4

(57)

Waste Outlets  

(One each end)

(C)

RH End of case to the center of LH waste outlet

60 

1

/

(1530)

84 

1

/

(2140)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(308)

12 

1

/

(308)

12 

1

/

(308)

Cooler wall to center of waste outlets

42 (1067)

42 (1067)

42 (1067)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Cooler wall to center of refrigeration outlet

1

/

(108)

1

/

(108)

1

/

(108)

(D)

RH end of case to center of refrigeration outlet

69 

1

/

(1759)

93 

1

/

(2369)

141 

3

/

(3591)

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

D6X-URLE 

Technical Data Sheet 

2 of 9

Engineering

Plan Views

B

Front

C

L

Upper Electrical 

Box

Upper Refrigeration 
Outlet

A

Cooler Wall

Canopy 

Bumper

Waste 
Outlet

43

 

(1092)

C

12 

1

/

(308)

Splashguard

Waste 
Outlet

D

Dimensions shown as in. & (mm).

Rear Load

Ultra Low Front Dairy

09-2007

Note: ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
Case to case connections are made in the electrical box at the top of 
the case.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Содержание D6X-URLE

Страница 1: ...rn 2 0058698 Fan Motor Return MO 4410102 0124150 Fan Blade FB 0124150 7W Energy Efficient Fan Assembly Return 0477654 Fan Motor Return MO 4410545 0124150 Fan Blade FB 0124150 THERMOSTATS C Optional Ad...

Страница 2: ...Box 2 1 4 57 2 1 4 57 2 1 4 57 Waste Outlets One each end C RH End of case to the center of LH waste outlet 60 1 4 1530 84 1 4 2140 132 3 8 3363 RH End of case to the center of RH waste outlet 12 1 8...

Страница 3: ...Only Pressure Defrost Termination Temp F NA Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 6 ft 2 0 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types...

Страница 4: ...40 0 60 0 90 56 72 108 Minimum Circuit Ampacity 120V 60Hz Standard 5 28 5 88 8 72 120V 50Hz Standard 6 32 7 12 10 58 230V 60Hz Export 2 76 3 08 4 52 230V 50Hz Export 3 04 3 64 5 36 120V 60Hz Energy E...

Страница 5: ...isplay Area 3 Sq Ft Ft 5 73 ft2 ft 1 75 m2 m Shelf Area 4 Sq Ft Ft 9 86 ft2 ft 3 01 m2 m 1 Refrigerated Volume ft3 m3 Unit of Length ft m 2 Refrigerated Volume less shelving and other unusable space R...

Страница 6: ...BL R BL R R R B 2 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Refrigeration Thermostat To Condensing Unit Light Blue 3 4 6 Discharge Air Fans 2 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROW...

Страница 7: ...3044 2483 U S A WWW HUSSMANN COM Doors Fully Closed NOTE Consult Ultra Low Front Installation manual for instructions on connecting the merchandiser to the cooler Rear View of 6 Foot Dairy Merchandise...

Страница 8: ...ON Bridgeton MO 63044 2483 U S A Doors Fully Closed NOTE Consult Ultra Low Front Installation manual for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Dairy Merchandise...

Страница 9: ...M 69 1 2 80 7 8 NOTE Consult Ultra Low Front Installation manual for instructions on connecting the merchandiser to the cooler Rear View of 12 Foot Dairy Merchandiser 41 1 2 D o o r s F u l l y C l o...

Отзывы: