background image

3 of 8

P/N 0463872_D

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

D6NX-LEP

U

NLIT

L

IT

P

EG

*

Discharge Air °F

33

31

31

Evaporator °F

28

26

26

Unit Sizing °F

26

24

24

Btu/hr/ft — Unlit Shelves

D6NX-LEP

‡‡

Parallel

Conventional

U

NLIT

1545

1610

P

EG

*

1690

1765

* Hussmann Peg Shelves (Deli only).

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

Frequency Hrs

12

Defrost Water (lb/ft/day)

10.5

(± 15% 

based on case configuration and

product loading).

O

FFTIME

D6NX-LEP

Temp Term °F

48

Failsafe Minutes

30

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

**

D6NX-LEP

19°F / 9°F

Indoor Unit Only, Pressure Defrost

Termination**

48°F

**Use a Temperature Pressure Chart to

determine PSIG conversions.

Estimated Charge (lb)***

D6NX-LEP

4 ft

1.4

6 ft

1.9

8 ft

2.7

12 ft

3.9

***This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

26 

3

/

(680)

3

/

(120)

25 

1

/

4   

(641)

37

 

(940)

28 

7

/

(734)

25 

3

/

8

 

(644)

66 

5

/

8

 

(1693)

34 

5

/

8

 

(878)

FAN

L

17 

1

/

4

 

(438)

3 In. 

(77 mm) 

Required 

Air Gap

87

 

(2220)

1

/

(183)

19 

5

/

8

 

(499)

5

/

8

 

(92)

21 

1

/

(540)

7

/

8

 

(123)

60

 

(1524)

Electrical 

Case to Case 

Connections

12 

1

/

(311)

Refrigeration 

Outlet

Impact  

Excel

D6NX-LEP

Dairy & Delicatessen

Dimensions shown as in. and (mm).

Multi-deck, Narrow Footprint, 6 Display Levels, Low Front

D6NX-LEP

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Содержание D6NX-LEP

Страница 1: ...B 4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780...

Страница 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Страница 3: ...TROLS Low Pressure Backup Control CI CO D6NX LEP 19 F 9 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb D6NX LEP...

Страница 4: ...230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 5...

Страница 5: ...70 m3 m ARI Total Display Area 3 Sq Ft Ft 5 25 ft2 ft 1 60 m2 m Shelf Area 4 Sq Ft Ft 8 81 ft2 ft 2 69 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Страница 6: ...R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy 4 3 4 4 Connector W B BL BL R BL R R R Optional Light...

Страница 7: ...RAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits...

Страница 8: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...