background image

4 of 6

D5LEP

LUS

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

D5LEP

LUS

Dairy & Delicatessen

Electrical Data

Number of Fans 

8 ft

12 ft

Refrigeration – 9W

2

3

Export – 9W

2

3

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.40

2.10

110

165

Energy Efficient (120V 60Hz)

0.76

1.14

50

75

Export (230V 50Hz)  

0.76

1.14

114

171

Constant On Anti-sweat Heaters

NA

NA

NA

NA

Cycling Anti-sweat Heaters

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans 

1.60

2.30

With Energy Efficient Fans 

0.96

1.34

With Export Fans (230V 50Hz) 

0.96

1.34

Maximum Over Current Protection 120V

20

20

Export (230V 50Hz)

15

15

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

NA

NA

NA

Gas Defrost Heaters (208V)

NA

NA

NA

NA

Standard Lighting

8 ft

12 ft

8 ft

12 ft

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Rows Canopy 

1.02

1.54

118

170 

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

4 Rows of Shelves

2.04

3.08

236

340

Содержание D5L-EP

Страница 1: ...geration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS C 0376409 Ballast Electronic 2 lamps 3 C 0376410 Ballast Electronic 3 lamps 3 D Fluorescent Lamp 4 Replace with like fixtures D5LEPLUS Data Sheet Set P N 0445920C NSF Certified March 2005 We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do n...

Страница 2: ... raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clea...

Страница 3: ... Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb D5LEPLUS 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End in 1 1 2 Each Insulated Partition in 1 1 2 3 of 6 P N 0445920C HUSSMANN...

Страница 4: ... Minimum Circuit Ampacity With Standard Fans 1 60 2 30 With Energy Efficient Fans 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1...

Страница 5: ...k W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Страница 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...

Отзывы: