Hussmann CHINO CID Скачать руководство пользователя страница 9

Rev. 0508 

9

Cleaning Glass and Mirrors

Only  use  a  soft  cloth  and  water  for  cleaning  any  glass 

or  mirrored  components.  Be  sure  to  rinse  and/or  dry 

completely.

Never  use  hot  water  on  cold  glass  surfaces!  It  may 

shatter and cause serious injury!

 Allow glass surfaces 

to warm first.

                          

CLEANING PRECAUTIONS

When cleaning:

• Do not use high pressure water hoses

• Do not introduce water faster than waste outlet can drain

• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN

• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL 

   BASE (these will dissolve the butyl sealants) or an AMMONIA BASE 

    (this will corrode the copper componets of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY

• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS  

   (these will mar the finish)

plexiglass and Acrylic Care

Improper cleaning not only accelerates the cleaning cycle 

but also degrades the quality of this surface. Normal daily 

buffing motions can generated static cling attracting dust to 

the surface. Incorrect cleaning agents or cleaning cloths can 

cause micro scratching of the surface, causing the plastic 

to haze over time.

Cleaning

Hussmann recommends using a clean damp chamois, or a 

paper towel marketed as dust and abrasive free with 

210

®

 

plastic Cleaner and polish

 available by calling Sumner 

Labs at 

1-800-542-8656

. Hard, rough cloths or paper towels 

will scratch the acrylic and should not be used.

Antistatic Coatings

The 

210

®

 has proven to be very effective in not only cleaning 

and  polishing  the  Plexiglass  surface,  but  also  providing 

anti-static and anti-fog capabilities. This product also seals 

pores and provides a protective coating.

Installing perimeter plexiglass

1.   If necessary, remove Boston cart bumper

.   Loosen screws holding Boston onto case. If a piece 

of front plexiglass has to be removed, gently slide it 

upwards taking care not to damage foam located on 

inside of glass.

3.   Keep the retaining plug, located at the joint of the 

plexiglass.

4.   Make sure foam is between plexiglass and support.

5.  Slide plexiglass down.

6.  Replace retaining plug.

7.   Tighten screws.

8.  Replace cart bumper.

9.   Follow joining instructions where necessary.

User Information (Cont'd)

Maintenance

BEFORE SERVICING

Always disconnect electrical power at the main 

disconnect when servicing or replacing any

electrical component.

This includes (but not limited to) Fans, Heaters,

Thermostats and Lights.

Replacing Fluorescent Lamps

Fluorescent  lamps  are  furnished  with  a  shatterproof 

protective coating. The same type of lamp with protective 

coating must be used if replaced. 

This lamp has been treated to resist breakage and must be 

replaced with a similarly treated lamp in order to maintain

compliance with NSF Standards. 

NSF CODE 4.28.1

Contact HUSSMAN Chino for replacement.

1-800-395-9229 X 2131

T-5 Bulbs

Please note: T-5 lights must be turned off and on after bulb 

replacement.

Evaporator Fans

The evaporator fans are located at the center front of these 

merchandisers directly beneath the display pans. Should 

fans or blades need servicing, always replace fan blades 

with the raised embossed side of the blade 

TOWARD THE 

MOTOR.

Содержание CHINO CID

Страница 1: ...CID ISLAND CHEESE DELI CASE p n IGIC CID 0508 INSTALLATION OPERATION GUIDE CHINO CID ISLAND CHEESE DELI CASE Rev 0508 Installation Operation Manual...

Страница 2: ...Self Service Island Display including 5 and 6 Crowns and 4 Center Modules available as standard refrigerated med low temp and hot Shipping Damage All equipment should be thoroughly examined for shipp...

Страница 3: ...Rev 0508 Cut and Plan Views...

Страница 4: ...he store floor B When wedges are involved in a lineup set them first All cases were leveled and joined prior to shipment to insure the closest possible fit when cases are joined in the field When join...

Страница 5: ...nd product losses Please follow the recommendations listed below when installing condensate drains to insure a proper installation 1 Never use pipe for condensate drains smaller than the nominal diame...

Страница 6: ...case setup the connecting point in the store may be 5 8 7 8 or 11 8 Refer to the particular case you are hooking up Refrigerant lines should be sized as shown on the refrigeration legend furnished by...

Страница 7: ...ntended for computerized scales with a five amp maximum load not for large motors or other high wattage appliances It should be wired to a dedicated circuit Finishing Touches Plexiglass Joining Instru...

Страница 8: ...d product life at the factory The use of higher output fluorescent lamps H O and V H O will shorten the shelf life of the product Case Cleaning Long life and satisfactory performance of any equipment...

Страница 9: ...very effective in not only cleaning and polishing the Plexiglass surface but also providing anti static and anti fog capabilities This product also seals pores and provides a protective coating Insta...

Страница 10: ...Check fixture loading Overstocking case will affect its proper operation 3 If frost is collecting on fixture and or product check that Humidity Control is working properly and that no outside doors or...

Страница 11: ...120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L CAP UNUSED RED LEAD LIGHT SWITCH BUNDLE COLOR...

Страница 12: ...AM LH3 120 L CAP UNUSED RED LEAD LIGHT SWITCH BUNDLE COLOR ORANGE 115 VAC 50 60 Hz M M M 115 VAC 50 60 Hz BUNDLE COLOR BROWN 115 VAC 50 60 Hz BUNDLE COLOR BLACK WHITE EVAPORATOR FAN MOTORS 3 GE 9 W 11...

Страница 13: ...25 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L LIGHT SWITCH BUNDLE COLOR ORANGE 115 VAC 50 60 Hz 115 VAC 50 60 Hz BUNDLE COLOR BROWN 115 VAC 50 60 Hz BUNDLE COLOR BLACK WHITE EVAPORA...

Страница 14: ...ST 125 01 3266 FULHAM LH3 120 L LIGHT SWITCH BUNDLE COLOR ORANGE 115 VAC 50 60 Hz 115 VAC 50 60 Hz BUNDLE COLOR BROWN 115 VAC 50 60 Hz BUNDLE COLOR BLACK WHITE EVAPORATOR FAN MOTOR 1 GE 9 W 115 VAC SU...

Страница 15: ...z M M M 115 VAC 50 60 Hz BUNDLE COLOR BROWN 115 VAC 50 60 Hz BUNDLE COLOR BLACK WHITE EVAPORATOR FAN MOTORS 3 GE 9 W 115 VAC SUCTION SOLENOID OPTIONAL T STAT OPTIONAL BALLAST 125 01 3266 FULHAM LH3 12...

Страница 16: ...les and Hot Wells b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c Complete start up...

Страница 17: ...e opening c READING It should first be determined that the refrigerator is refrigerating and has operated at least one hour since the end of the last defrost period The thermometer reading should be m...

Страница 18: ...rea s Cleaning practices particularly with respect to proper refrigerator unloading and warm up must be in accordance with applicable recommendations 1 1 Cleaning of non frozen food equipment should i...

Страница 19: ...e cleaning of equipment within the compartment and the hot area s Cleaning practices particularly with respect to proper refrigerator unloading and warm up must be in accordance with applicable recomm...

Страница 20: ..._________________________________ _______________ ___________________________________________________________________________________________________ _______________ __________________________________...

Отзывы: