background image

4 of 11

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C3X-LGEP

Technical Data Sheet

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—12W

1

2

3

Number of Fans—7W

2

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.65

1.00

1.30

1.95

50

78

100

150

120V

50Hz

Standard

0.75

1.10

1.50

2.25

57

84

114

171

230V

60Hz

Export

0.33

0.50

0.66

0.99

50

78

100

150

230V

50Hz

Export

0.38

0.56

0.76

1.14

57

84

114

171

120V

60Hz

Energy Efficient

0.30

0.38

0.60

0.90

18

28

36

54

230V

60Hz

Energy Efficient

0.15

0.20

0.30

0.45

18

28

36

54

Minimum Circuit Ampacity

120V

60Hz

Standard

0.85

1.20

1.50

2.15

120V

50Hz

Standard

0.95

1.30

1.70

2.45

230V

60Hz

Export

0.53

0.70

0.86

1.19

230V

50Hz

Export

0.58

0.76

0.96

1.34

120V

60Hz

Energy Efficient

0.50

0.58

0.80

1.10

230V

60Hz

Energy Efficient

0.35

0.40

0.50

0.65

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Anti-sweat Heaters

120V

50/60Hz Standard

0.10

0.15

0.20

0.30

12

18

24

36

Standard Lighting (T-8 Fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting (T-8 Fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

1 Row Rail Light

NA — Glass front does not accept rail light

Optional Shelf Lighting (T-8 Fluorescent)

1 Row of Shelves

0.26

0.51

0.51

0.77

30

59

59

85

2 Rows of Shelves

0.51

1.02

1.02

1.54

59

118

118

170

3 Rows of Shelves

0.77

1.53

1.53

2.31

89

177

177

255

Optional Always*Bright LED Lighting

1 Row of Shelves

0.15

0.19

0.26

0.38

18

23

31

45

2 Rows of Shelves

0.26

0.34

0.47

0.67

31

41

56

80

3 Rows of Shelves

0.38

0.53

0.74

1.11

45

63

89

133

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

Impact  

Excel

C3X-LGEP

Dairy / Delicatessen
Precut and Packaged Produce

Содержание C3X-LGEP

Страница 1: ... Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 HEATERS C Canopy Anti Sweat Heater 3 0488621 4 ft HE 4850616 0488622 6 ft HE 4850617 0488623 8 ft HE 4850618 0488624 12 ft HE 4850619 LAMPS BALLASTS ...

Страница 2: ...ween edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of st...

Страница 3: ...G conversions Estimated Charge lb C3X LGEP 4 ft 1 9 6 ft 2 8 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Dimensions shown as inches and mm P N 0494876_B 3 of 11 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 66 3 8 1696 31 5 8 804 4 3 4 120 30 1 4 768 42 1064 33 1 2 851 26 1 4 665 C3X LGEP 30 ...

Страница 4: ...40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 12 18 24 36 Standard Lighting T 8 Fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 Fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 1 Row Rail Light NA Glass front does not accept...

Страница 5: ...ARI Total Display Area 3 Sq Ft Ft 4 07 ft2 ft 1 24 m2 m Shelf Area 4 Sq Ft Ft 6 02 ft2 ft 1 84 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4...

Страница 6: ... 5 4 4 5 5 5 5 Optional Two Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ...

Страница 7: ...0V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 5 5 5 B W 6 ft or 8 ft case 12 ft case BL BL R BL BL BL R W R B R 4 BL BL BL R R R R 5 5 5 B W BL BL R BL BL BL R W R B R 4 BL BL BL R R R R Canop...

Страница 8: ...BL 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixtur...

Страница 9: ... BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for ...

Страница 10: ... ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of light channel 2 Lower light channel which will pivot on hinge 3 Service or replace ballasts as required 4 Reassemble items as they were originally installed NOTE Rail lamp ballast is located in the ...

Страница 11: ... This case is designed for three 3 shelves The depth of the shelves used are critical to case performance The use of peg shelves is NOT recommended on C3X LGEP cases Depth and angle requirements are listed below Top Shelf Shelf Depth Shelf Angle 12 inches 0º 10º 15º 30º 45º 14 inches 30º 45º Second Shelf Shelf Depth Shelf Angle 14 inches 0º 10º 15º 30º 45º 16 inches 30º 45º Third Shelf Shelf Depth...

Отзывы: