Hussmann BEXD Скачать руководство пользователя страница 2

Waste Outlet

Refrigeration
Outlet

Water Seal

Electrical 

Access Area

 

(Gray

)

Front

Base Rail

31 

1

/

8

(1137)

44

 

3

/

4

(1137)

46 

1

/

2

(1181)

38

 

3

/

4

(984)

44 

3

/

8

(1127)

53 

1

/

2

(1335)

53 

1

/

2

(1350)

1

/

2

(142)

7

/

8

(98)

A

B

C

BEXD 

Data Sheet

2 of 5

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as in. and (mm).

BEXD

Medium Temperature

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

1

/

4

(2445)

144 

1

/

2

(3670)

Maximum O/S dimension back to front 

(with bumper)

53 

1

/

2

(1350)

53 

1

/

2

(1350)

Back of case to front of splashguard

45 

3

/

(1161)

45 

3

/

(1161)

Back of case to O/S edge of front skid rail

38 

3

/

(984)

38 

3

/

(984)

Width of skid rail

1

/

(54)

1

/

(54)

RH end of case to outside edge of external support

1

/

4

(32)

1

/

4

(32)

Distance between edges of external support and center support

44 

5

/

(1135)

44 

5

/

(1135)

Distance between edges of center supports

NA

48 

1

/

8

(1222)

Stub-up area between front skid rail and splashguard

5

/

8

(193)

5

/

8

(193)

Electrical Service                         

(Electrical Field Wiring connection point)

Length of electrical raceway

32 

3

/

(831)

32 

3

/

(831)

(B)

RH End of case to center of farthest knockout

90 

1

/

(2292)

140 

1

/

(3569) 

Back of case to center of knockout

46 

1

/

(1181)

46 

1

/

(1181)

RH End of case to RH end of raceway

57 

1

/

(1460)

107 

5

/

(2734)

Waste Outlet

(C)

RH End of case to the center of waste outlet

19 

3

/

(622)

76 

1

/

(1943)

LH End of case to the center of waste outlet

38 (965)

76 

1

/

(1943)

Back O/S of case to center of waste outlet

44 

3

/

(1127)

44 

3

/

(1127)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

Refrigeration Outlet

Back of case to center of refrigeration outlet

44 

3

/

(1136)

44 

3

/

(1136)

RH end of case to center of refrigeration outlet

1

/

(142)

1

/

(142)

Содержание BEXD

Страница 1: ...aporator 1 0392457 Standard Energy Efficient 0409511 Fan Blade B 0261933 Standard Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item HEATERS C 0401605 Nosing Anti sweat Heater 8 ft 3 0401606 Nosing Anti sweat Heater 12 ft Note Changed items have been underlined P N 0459615 BEXD Data Sheet Set P N 0459615 NSF Certified March 2004 ...

Страница 2: ...pport and center support 44 5 8 1135 44 5 8 1135 Distance between edges of center supports NA 48 1 8 1222 Stub up area between front skid rail and splashguard 7 5 8 193 7 5 8 193 Electrical Service Electrical Field Wiring connection point Length of electrical raceway 32 3 4 831 32 3 4 831 B RH End of case to center of farthest knockout 90 1 4 2292 140 1 2 3569 Back of case to center of knockout 46...

Страница 3: ...iguration and product loading OFFTIME Failsafe minutes 70 ELECTRIC OR GAS Not Available Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control BEXD CI CO Temp F 30 20 Indoor Unit Only Pressure Defrost Termination Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser BEXD Drip Pipe in 5 8 Liquid Line in 3 8 Suction Line in 7 8 E...

Страница 4: ... 3 120V 60hz System Export 9W 230V 50 hz NA NA Amperes Watts Merchandiser 8 ft 12 ft 8ft 12 ft Fans Standard 0 58 0 87 48 72 Export 230V 50 hz NA NA NA NA Nosing Anti sweat Heaters 120V 0 67 1 0 80 120 Minimum Circuit Ampacity With Standard Fans 0 6 0 9 With Export 230V 50 hz Fans NA NA Maximum Over Circuit Protection 120V 20 20 Lighting Standard None Optional None ...

Страница 5: ...ING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only BROWN BAND Fans BROWN BAND 120V POWER 120V NEUTRAL 1 120V POWER Anti Sweat Heaters Rear Rail 3 PURPLE BAND PURPLE BAND 120V NEUTRAL Fan Wiring Offtime Defrost 2 3 Fans ...

Отзывы: