background image

9

P/N 0512887_A  —  1 October 2009

Safe-NET software Version 9.03 or later

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

ARV-570 & ARV-1230

©2009 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Hussmann Beer Merchandiser

Escape

To leave a Menu and return to the default 
display, press the UP and DOWN buttons on
the Safe-NET display module simultaneously.
If a valid pass code has been entered it will
remain active for the remainder of the 
5-minute time out period. This allows exiting
one menu and entering another to modify a
value without having to re-enter the pass code.

Defrosts

The unit must go into defrost mode at least
twice in each 24 hours to maintain optimal 
performance. During defrost, the temperature
display may move up 2-3°F (1-2°C). Avoid 
opening the door during the defrost cycle. 

Defrost is necessary because the Hussmann
Beer Merchandiser operates at temperatures
below freezing (26°F/ –3.3°C). Defrosting is
done automatically with Safe-NET. 

Defrost water drains to a drip pan where it
evaporates. Restricting airflow around the 
bottom of a Hussmann Beer Merchandiser
may delay or prevent complete evaporation.

In the event of power loss, the optional real time
clock will keep its settings for at least one week
once the battery is fully charged. The real time
clock battery is automatically recharged when
the unit is plugged in. 

The Hussmann Beer Merchandiser Safe-NET
comes with two defrosts preset: one at 0200
and one at 1400. If the preset defrost times are
acceptable for your business, no settings need
to be changed. Replace the Safe-NET cover
and grille.

If the preset times need to be changed for your
business schedule, or if additional defrosts are
needed because the unit is in an extreme envi-
ronment, the Safe-NET controller can be set
to meet the requirements of your business.

Real Time Clock

(Hussmann Aftermarket Part CC.4440746)

Содержание ARV-1230

Страница 1: ...ARV 570 ARV 1230 Owner s Manual P N 0512887_A 1 October 2009 Beer Merchandiser P N0512887A...

Страница 2: ...ach case carries a label identifying the type of application for which the case was certified ANSI NSF 7 Type II Display Refrigerator Freezer Beverage Cooler Intended for 80 F 55 RHAmbientApplication...

Страница 3: ...XICO 1 800 522 1900 WWW HUSSMANN COM Hussmann Beer Merchandiser ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 ARV 570 ARV 1230 To reduce the risk of fire electrical shock or injury when using you...

Страница 4: ...Or Damage When loss or damage is not apparent until after equipment is uncrated retain all packing mate rials and submit a written request to the carrier for inspection within 15 days UNCRATE Use the...

Страница 5: ...s by turning the thumb screws clock wise Carefully lift the unit to insert shims as needed to prevent the chamber from rolling or tilting Thumbscrew locks are packed in an envelope inside the merchand...

Страница 6: ...r Light Switch Hussmann Beer Merchandiser light switches are located on the top right side of the interior INSTALL SHELVES ARV 570 Four rows of flat shelves OR Five rows of flat wire shelves OR Four r...

Страница 7: ...e product stop goes to the rear for flat shelves The ARV 1230 shelves have product stops toward the center of the merchandiser 4 Use the bracket numbering on each side to guide placement of shelves Sh...

Страница 8: ...d 3A for ARV 570 and should not be used for anything other than a lighted sign requiring the stated Amperage or less The plug is protected by a separate fuse The fuse can be replaced with a like fuse...

Страница 9: ...ows Safe Net 9 03 1 Version C570 Case Model OR C123 FOR TWO DOORS 75 2 temperature of air entering the evaporator 1 The Version will change dependent on current version installed 2 The temperature of...

Страница 10: ...SELECT button EASy is displayed Press the DOWN button until you see CLOC Press SELECT and the MINUTES begin to flash With minutes flashing use the UP or DOWN button until the correct minutes are disp...

Страница 11: ...g the defrost cycle Defrost is necessary because the Hussmann Beer Merchandiser operates at temperatures below freezing 26 F 3 3 C Defrosting is done automatically with Safe NET Defrost water drains t...

Страница 12: ...the number of defrosts that occur in a 24 hour period beginning with the StAr first defrost parameter The maximum number of defrosts allowed in a 24 hour period is 8 The defrosts are spaced evenly acr...

Страница 13: ...er closing for the night so that it can pull down to temperature overnight 3 Stock bottles upright only 4 Do not add warm product during selling hours The LED display shows the calculated actual beer...

Страница 14: ...or acidic based cleaners on any interior surfaces A hose on display or interior lights or any other electrical connection Do First disconnect electrical power Remove the product and all loose debris...

Страница 15: ...eaned at least once each month A dirty coil will slow product cooling significantly and can increase energy consumption by as much as 20 Remove screws on each side of the louvered front grille then li...

Страница 16: ...sleeve 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes before stocking with fresh product 14 Safe NET software Version 9 03 or later 1 October 2009 P N...

Страница 17: ...eeve 8 Reassemble in reverse order 9 Plug the unit in 10 Allow the unit to run for at least 30 min utes before stocking with fresh product 15 P N 0512887_A 1 October 2009 Safe NET software Version 9 0...

Страница 18: ...e connector from each end 5 Remove from holding clips 6 Replace the lamp and reconnect connectors 7 Reassemble in reverse order 8 Plug the unit in 9 Allow the unit to run for at least 30 minutes befor...

Страница 19: ......

Страница 20: ...roduct Poor airflow around unit Reposition unit to provide space on all sides Evaporator blocked by ice Verify that door is sealing completely Heavy use in high humidity reset Safe NET controller to i...

Страница 21: ......

Страница 22: ...rrants all sealed multi glass assemblies If within the warranty period it can be proven to the satisfaction of Hussmann s warranty administration organization that there is impaired visibility through...

Страница 23: ...CLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS AND HUSSMANN NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF ITS...

Страница 24: ......

Отзывы: