COOLING SYSTEM 16
95
E01306-10
Main work
–
Stand the motorcycle upright on a horizontal surface.
–
Remove cap
1
of the compensating tank.
–
Check the antifreeze in the coolant.
−
25 …
−
45 °C (
−
13 …
−
49 °F)
» If the antifreeze in the coolant does not match the speci-
fied value:
–
Correct the antifreeze in the coolant.
–
Check the coolant level in the compensating tank.
The coolant level must be between
MIN
and
MAX
.
» If the coolant level does not match the specified value:
–
Correct the coolant level.
Coolant (
–
Mount the cap of the compensating tank.
E01305-10
–
Remove radiator cap
2
.
–
Check the antifreeze in the coolant.
−
25 …
−
45 °C (
−
13 …
−
49 °F)
» If the antifreeze in the coolant does not match the speci-
fied value:
–
Correct the antifreeze in the coolant.
–
Check the coolant level in the radiator.
The radiator must be filled completely.
» If the coolant level does not match the specified value:
–
Check the coolant level and the reason for the loss.
Coolant (
» If you had to add more coolant than the specified
amount:
> 0.20 l (> 0.21 qt.)
–
Fill/bleed the cooling system.
–
Mount the radiator cap.
Finishing work
–
Install the right side cover.
–
Mount the front rider's seat. (
–
Mount the passenger seat. (
–
Install the bag carrier. (