Greek – 87
™À¡Δ∏ƒ∏™∏
™¯Ë‰È¿ÁÚ·ÌÌ· ·ÓÙÈÌËÙÒÈÛ˘ ÚÔ‚ÏËÌ¿ÙˆÓ
Δ· ÌËӇ̷ٷ ÛÊ¿ÏÌ·ÙÔ˜ ÂÌÊ·Ó›˙ÔÓÙ·È Â›Ù ÛÙË ÁÏÒÛÛ· Ô˘ ¤¯ÂÙ ÂÈϤÍÂÈ ÛÙÔ ÚÔ˚fiÓ Â›Ù ÛÙ· ∞ÁÁÏÈο.
* XX ‰È·ÊÔÚÂÙÈÎÔ› ·ÚÈıÌÔ› ·Ó¿ÏÔÁ· Ì ÙÔ ÂÚÁ·ÏÂ›Ô Ô˘ ¤¯ÂÈ Û˘Ó‰Âı› ÛÙË ÌÔÓ¿‰· ÈÛ¯‡Ô˜.
∫ˆ‰ÈÎfi˜
ÛÊ¿ÏÌ·ÙÔ˜
ªËӇ̷ٷ ÛÊ¿ÏÌ·ÙÔ˜
¢È·‰Èηۛ·
μ‹Ì·Ù·
F0101
Over current detected
ŒÓÙ·ÛË ËÓËÚÁÔ‡ ËÚÁ·Ï˛Ԣ
Ôχ ˘„ËÏ‹
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0103
Fault detected in hardware
™Ê¿ÏÌ· ˘ÏÈÎÔ‡
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0104
Error detected on the voltage bus ™Ê¿ÏÌ· Ù¿Û˘ ËÚÁ·Ï˛Ԣ
∏ϤÁÍÙË ÙËÓ ÙÚÔÊÔ‰ÔÛ›·
F0105
High voltage detected on voltage
bus. Check the power supply
connection.
¶Ôχ ÈÛ¯˘Ú‹ ËÊ·ÚÌÔÁ‹
ÊÚ¤ÓÔ˘
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0106
Temperature in the IGBT module
too high
ÀËÚı¤ÚÌ·ÓÛË ËÁ‹˜
ÈÛ¯‡Ô˜
∞˘Í‹ÛÙ ÙË ÚÔ‹ ÙÔ˘ „˘ÎÙÈÎÔ‡ ˘ÁÚÔ‡.
μ‚·Èˆı›Ù fiÙÈ ÙÔ ÓÂÚfi Ô˘ ¯ÚËÛÈÌÔÔÈ›ٷÈ
Â›Ó·È Î·ı·Úfi, ÒÛÙ ӷ ÌËÓ ÊÚ¿ÍÔ˘Ó ÔÈ ‰›Ô‰ÔÈ ÙÔ˘
ÓÂÚÔ‡. °È· Ó· ‰Â›Ù ÙȘ ÚԉȷÁڷʤ˜ Ô˘
ÈÛ¯‡Ô˘Ó ÁÈ· ÙË ÚÔ‹, ÙË ıÂÚÌÔÎÚ·Û›· Î·È ÙËÓ ›ÂÛË
ÙÔ˘ ÓÂÚÔ‡, ·Ó·ÙÚ¤ÍÙ ÛÙ· Δ¯ÓÈο ÛÙÔȯ›·.
F0107
Emergency stop switch pressed
√ ‰È·ÎfiÙ˘ ‰È·ÎÔ‹˜
ËÎÙ¿ÎÙÔ˘ ·Ó¿Á΢ ˛ӷÈ
·ÙË̤ÓÔ˜.
∏·Ó·Ê¤ÚËÙË ÙÔ ‰È·ÎfiÙË ‰È·ÎÔ‹˜ ËÎÙ¿ÎÙÔ˘
·Ó¿Á΢
FXX08*
High motor temperature detected
∏ ıËÚÌÔÎÚ·Û›· ÌÔÙ¤Ú ÙÔ˘
ËÚÁ·Ï˛Ԣ Ë›Ó·È Ôχ
˘„ËÏ‹
∞˘Í‹ÛÙ ÙË ÚÔ‹ ÙÔ˘ „˘ÎÙÈÎÔ‡ ˘ÁÚÔ‡.
μ‚·Èˆı›Ù fiÙÈ ÙÔ ÓÂÚfi Ô˘ ¯ÚËÛÈÌÔÔÈ›ٷÈ
Â›Ó·È Î·ı·Úfi, ÒÛÙ ӷ ÌËÓ ÊÚ¿ÍÔ˘Ó ÔÈ ‰›Ô‰ÔÈ ÙÔ˘
ÓÂÚÔ‡. °È· Ó· ‰Â›Ù ÙȘ ÚԉȷÁڷʤ˜ Ô˘
ÈÛ¯‡Ô˘Ó ÁÈ· ÙË ÚÔ‹, ÙË ıÂÚÌÔÎÚ·Û›· Î·È ÙËÓ ›ÂÛË
ÙÔ˘ ÓÂÚÔ‡, ·Ó·ÙÚ¤ÍÙ ÛÙ· Δ¯ÓÈο ÛÙÔȯ›·.
F0109
Low voltage detected on voltage
bus. Check the power supply
connection.
∏ÛˆÙËÚÈÎfi ÛÊ¿ÏÌ· ËÁ‹˜
ÈÛ¯‡Ô˜
∏ϤÁÍÙË ÙËÓ Ë›ÛÔ‰Ô ÈÛ¯‡Ô˜ ‹ ËÈÎÔÈÓˆÓ‹ÛÙË ÌË
ÙÔ Û¤Ú‚È˜
F0110
Cooling fan fault detected. Check
the cooling fan
¢˘ÛÏËÈÙÔ˘ÚÁ›· ·ÓËÌÈÛÙ‹Ú·
∏ϤÁÍÙË ÙÔÓ ·ÓËÌÈÛÙ‹Ú· Î·È ·ÓÙÈηٷÛÙ‹ÛÙË
ÙÔÓ, Ë¿Ó Ë›Ó·È ··Ú·›ÙËÙÔ
F0111
The clock has stopped, please
correct it if neccessary.
ΔÔ ÚÔÏfiÈ ÛÙ·Ì¿ÙËÛË
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û¤Ú‚È˜ ÁÈ· ·ÏÏ·Á‹
Ì·Ù·Ú›·˜
F0112
Low input voltage detected
¶Ôχ ¯·ÌËÏ‹ Ù¿ÛË ËÈÛfi‰Ô˘
∏ϤÁÍÙË ÙËÓ ËÏ¿¯ÈÛÙË ÈÛ¯‡ ËÈÛfi‰Ô˘ ÛÙÔ
ËÁ¯ËÈÚ›‰ÈÔ
F0113
High input voltage detected
¶Ôχ ˘„ËÏ‹ Ù¿ÛË ËÈÛfi‰Ô˘
∏ϤÁÍÙË ÙË Ì¤ÁÈÛÙË ÈÛ¯‡ ËÈÛfi‰Ô˘ ÛÙÔ ËÁ¯ËÈÚ›‰ÈÔ
FXX14*
Tool temperature sensor error
detected
¢È·ÎÔ‹ ‹ ‚Ú·¯˘Î‡Îψ̷
ÛÙÔÓ ·ÈÛıËÙ‹Ú·
ıËÚÌÔÎÚ·Û›·˜.
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔÓ ·ÓÙÈÚfiÛˆÔ Û¤Ú‚È˜.
F0215
Travel motor has stopped
μÚ›ÛÎÂÙ·È ÛÙÔ ÙÂÚÌ·ÙÈÎfi
Ù˘ ÙÚԯȿ˜
∫·ı·Ú›ÛÙ ÙË Ú¿Á· ÙÔ˘ ÎfiÊÙË ÙÔȯ›ˆÓ ηÈ
‚‚·Èˆı›Ù fiÙÈ Ô ÎfiÊÙ˘ ÙÔȯ›ˆÓ Î·È Ë Ú¿Á·
Â›Ó·È ÛÙÂÚˆ̤ӷ.
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
∞ηı·Úۛ˜ ÛÙËÓ ÙÚԯȿ
∏ Ï›‰· ¤¯ÂÈ ÎÔÏÏ‹ÛÂÈ
F0216
Depth motor has stopped
∏ Ï›‰· ¤¯ÂÈ ÎÔÏÏ‹ÛÂÈ
μ‚·Èˆı›Ù fiÙÈ Ô ÎfiÊÙ˘ ÙÔȯ›ˆÓ Î·È Ë Ú¿Á·
Â›Ó·È ÛÙÂÚˆ̤ӷ.
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0117
Fault detected in hardware
™Ê¿ÏÌ· ˘ÏÈÎÔ‡
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0118
Fault detected in hardware
™Ê¿ÏÌ· ˘ÏÈÎÔ‡
∏ÈÎÔÈÓˆÓ‹ÛÙË ÌË ÙÔ Û˘ÓËÚÁË›Ô Û¤Ú‚È˜ Ë¿Ó ÙÔ
Úfi‚ÏËÌ· ËÈ̤ÓËÈ.
F0119
Temperature in the PP too high
ÀËÚı¤ÚÌ·ÓÛË ËÁ‹˜
ÈÛ¯‡Ô˜
∞˘Í‹ÛÙ ÙË ÚÔ‹ ÙÔ˘ „˘ÎÙÈÎÔ‡ ˘ÁÚÔ‡.
μ‚·Èˆı›Ù fiÙÈ ÙÔ ÓÂÚfi Ô˘ ¯ÚËÛÈÌÔÔÈ›ٷÈ
Â›Ó·È Î·ı·Úfi, ÒÛÙ ӷ ÌËÓ ÊÚ¿ÍÔ˘Ó ÔÈ ‰›Ô‰ÔÈ ÙÔ˘
ÓÂÚÔ‡. °È· Ó· ‰Â›Ù ÙȘ ÚԉȷÁڷʤ˜ Ô˘
ÈÛ¯‡Ô˘Ó ÁÈ· ÙË ÚÔ‹, ÙË ıÂÚÌÔÎÚ·Û›· Î·È ÙËÓ ›ÂÛË
ÙÔ˘ ÓÂÚÔ‡, ·Ó·ÙÚ¤ÍÙ ÛÙ· Δ¯ÓÈο ÛÙÔȯ›·.