English
–
29
F
F
F
G
G
H
E
G
C
D
Safety equipment
8.7 Dismantling the front handle and
start inhibitor - LiHD60X / LiHD70X
1
Dismantle the front handle and the right chassis
half.
See Chapter 7.5 - 7.6.
2
Dismantle the gear housing and motor.
See Chapter 10.2.
3
Uncouple the handle cables (A) from the control
unit and remove them through the hole (B) in the
chassis.
See figure 7.
4
Loosen the screws (10x) and carefully lift off the
handle half.
See figure 8.
5
Lift the relay with cables (C) and the loop (D) out of
the handle.
See figure 9.
6
Lift the start inhibitor (E), plastic clips (F 3x),
springs (G 3x) and spring (H) over the screw tower
out of the handle.
See figure 10.
Fig.7
Fig.8
Fig.9
Fig.10
A
B
WARNING!
Exercise care to ensure the spring
does not fly out and causes person-
al injury. Wear protective goggles!
Содержание LiHD50
Страница 1: ...Workshop Manual English LiHD50 LiHD60X LiHD70X ...
Страница 2: ......
Страница 5: ...English 5 Index ...
Страница 13: ...English 13 Service data Service data LiHD50 x2 1 Nm x8 2 3 Nm 4 mm x2 2 3 Nm 4 mm x11 2 3 Nm 4 mm ...
Страница 21: ...English 21 Diagnosis and troubleshooting ...
Страница 39: ...English 39 ...
Страница 43: ...English 43 Fig 9 Fig 8 LiHD60X LiHD70X Repair instructions LiHD60X LiHD70X ...
Страница 60: ...2012W33 115 73 09 26 ...