Maintenance

Introduction

WARNING: Read and understand the safety

chapter before you do maintenance on the

product.

To clean the product

CAUTION: Do not use a high-pressure

washer to clean the product.

• Use running water from a hose to clean the product.
• Remove concrete from the surfaces of the product

after each operation before the concrete becomes

hard.

• Remove grease and oil from the product.

To do maintenance on the concrete

vibrator

Maintenance is necessary after each 500 h of operation.
1. Put the vibrator head in a pipe vise.
2. Remove the end cap and the end shank.

Note: The end cap and the end shank has a left

hand thread.

3. Remove the flexible shaft from the vibrator head

shaft.

Note: The flexible shaft and the vibrator head shaft

has a right hand thread.

4. Remove the vibrator head shaft from the front of the

vibrator head housing.

5. Replace the O-rings, the sealing sleeve and the ball

bearing.
a) Lubricate the ball bearing before you install it.

6. Clean and lubricate the flexible shaft. Refer to

Lubrication on page 6

.

7. Assemble the vibrator head in the opposite

sequence.

CAUTION: Do not lubricate the vibrator

head housing, the vibrator head shaft or

the end cap. These parts must be clean

and dry when you assemble the vibrator

head.

Lubrication

Vibrator head

AA27 AA37 AA47 AA67 AA77 AZ26 AZ36 AZ46 AZ56

Grease type for the ball bearing 

1

Shell Alvania R3

Quantity of grease for the ball bearing, cm

3

1

1.25

1.50

1.75

1.75

1

1.25

1.50

1.75

Grease type for the flexible shaft 

2

Shell Gadus S2 V220AD 2

Quantity of grease for the flexible shaft

10–15 g/m

Storage and disposal

Storage

• Clean the product before storage.
• Keep the product in a dry and frost-free area.
• Keep the product in a locked area to prevent access

for children or persons that are not approved.

Disposal of the product

• Obey the local recycling requirements and applicable

regulations.

• When the product no longer is used, send it to the

dealer or discard it at a recycling location.

1

It is only necessary to lubricate when the bearing is replaced.

2

Lubricate the flexible shaft after each 500 h of operation.

6

970 - 001 - 28.01.2022

Содержание AA 27

Страница 1: ...AA 27 AA 37 AA 47 AA 67 AA 77 AZ 26 AZ 36 AZ 46 AZ 56 EN Operator s manual 2 9 ...

Страница 2: ... is incorrectly repaired the product is repaired with parts that are not from the manufacturer or not approved by the manufacturer the product has an accessory that is not from the manufacturer or not approved by the manufacturer the product is not repaired at an approved service center or by an approved authority Safety Safety definitions Warnings cautions and notes are used to point out speciall...

Страница 3: ...at high speed Make sure that all persons in the work area use approved personal protective equipment Remove loose objects from the work area Before you go away from the product stop the product and disconnect the power source Make sure that clothes long hair and jewelry do not get caught in moving parts Do not sit on the product Do not hit the product Make sure that you or other persons cannot get...

Страница 4: ...quipment WARNING Read the warning instructions that follow before you use the product Always use approved personal protective equipment when you operate the product Personal protective equipment cannot fully prevent injury but it decreases the degree of injury if an accident does occur Let your dealer help you select the correct personal protective equipment Regularly do a check of the condition o...

Страница 5: ...in the vibrator head hit the side of the vibrator head to start the vibration To operate the product CAUTION Do not make sharp bends or loops on the flexible shaft Sharp bends and loops increase the wear and decrease the lifetime of the flexible shaft CAUTION Do not use the product to move the concrete to the side 1 Fill concrete in equally thick layers 30 50 cm 12 19 in B 2 Put the vibrator head ...

Страница 6: ... it 6 Clean and lubricate the flexible shaft Refer to Lubrication on page 6 7 Assemble the vibrator head in the opposite sequence CAUTION Do not lubricate the vibrator head housing the vibrator head shaft or the end cap These parts must be clean and dry when you assemble the vibrator head Lubrication Vibrator head AA27 AA37 AA47 AA67 AA77 AZ26 AZ36 AZ46 AZ56 Grease type for the ball bearing 1 Shel...

Страница 7: ... 16 Max engine speed rpm 3000 3000 3000 3000 3000 3000 3000 3000 3000 Weighted effective acceler ation m s2 ft s2 3 4 2 46 1 56 3 52 2 66 3 16 2 00 5 22 2 42 8 27 Sound power level LWA measured dB A 5 83 86 87 93 Sound pressure level at work station dB A 6 69 72 73 79 3 Weighted effective acceleration measured in water driving one poker on the hose at 2 m from the end of the poker m s2 according t...

Страница 8: ...ating from 2020 and onwards complies fully with the following EU directives and regulations Directive Regulation Description 2006 42 EC relating to machinery 2014 30 EU relating to electromagnetic compatibility and that the following harmonized standards and or technical specifications are applied EN 12649 2008 A1 2011 EN ISO 12100 2010 Partille 2021 10 28 Martin Huber R D Director Concrete Surfac...

Страница 9: ...e following UK directives and regulations The Supply of Machinery Safety Regulations 2008 Electromagnetic Compatibility Regulations 2016 and that the following standards and or technical specifications are applied EN 12649 2008 A1 2011 EN ISO 12100 2010 Partille 2021 10 28 Martin Huber R D Director Concrete Surfaces Floors Husqvarna AB Construction Division Responsible for technical documentation ...

Страница 10: ...10 970 001 28 01 2022 ...

Страница 11: ...970 001 28 01 2022 11 ...

Страница 12: ...www husqvarnacp com Original instructions 1140439 26 2022 02 09 ...

Отзывы: